www.recom-power.com REV.: 3/2018 ECO-1
Features
Unregulated
Converters
High 6.4kVDC isolation
Wide operating temperature range from
-40°C to +90°C without derating
High capacitive load capability
Continuous short circuit protection
Efficiency up to 80% RK/H6 & RH/H6
Description
The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended
operating temperature range up to +90°C without derating, yet are lower cost than standard high
isolation converters. They are suitable for demanding industrial and high isolation test and measurement
applications.
DC/DC Converter
1 Watt
SIP7
Single and Dual
Output
UL60950-1 certified
CSA C22.2 No. 60950-1-07 certified
IEC60950-1 certified
IEC62368-1 certified
E224736
Selection Guide
Part nom. Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ. Load (1)
[VDC] [VDC] [mA] [%] [µF]
RK-xx3.3S/H6 5, 12, 15, 24 3.3 303 71-74 1000
RK-xx05S/H6 5, 12, 15, 24 5 200 74-77 1000
RK-xx12S/H6 5, 12, 15, 24 12 84 77-79 220
RK-xx15S/H6 5, 12, 15, 24 15 66 77-80 220
RH-xx3.3D/H6 5, 12, 15, 24 ±3.3 ±152 73-74 ±330
RH-xx05D/H6 5, 12, 15, 24 ±5 ±100 74-77 ±330
RH-xx12D/H6 5, 12, 15, 24 ±12 ±42 77-80 ±100
RH-xx15D/H6 5, 12, 15, 24 ±15 ±33 78-80 ±100
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load
Notes:
Note2: add suffix „K“ for Single output or suffix „H“ for Dual output
Model Numbering
Ordering Examples:
RK-123.3S/H6 = 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output, 6.4kVDC isolation
RH-0505D/H6 = 5VDC Input Voltage, 5VDC Output Voltage, Dual Output, 6.4kVDC isolation
6.4kVDC isolation
Single
6.4kVDC isolation
Dual
Input Voltage
Output Voltage
Input Voltage
Output Voltage
RK- __ __S/H6
RH- __ __D/H6
www.recom-power.com REV.: 3/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RK/H6 & RH/H6
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter capacitor
Input Voltage Range ±10%
Start-up Time 20ms
Internal Operating Frequency 80kHz
Minimum Load 0%
Output Ripple and Noise 20MHz BW limited 60mVp-p 120mVp-p
REGULATIONS
Parameter Condition Values
Output Accuracy ±5.0% max.
Line Regulation low line to high line, max. load ±1.2% of 1.0% Vin typ.
Load Regulation 10% to 100% load 10% max.
20
10
0
-10
15
5
-5
-15
-20
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
20
10
0
-10
15
5
-5
-15
-20
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
Accuracy vs. Load
Efficiency vs. Load
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
Single Output
Single Output
Dual Output
Dual Output
www.recom-power.com REV.: 3/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RK/H6 & RH/H6
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating @ free air convection (see graph) -40°C to +90°C
Operating Humidity non-condensing 5% - 95% RH max.%
MTBF according to MIL-HDBK-217F; G.B. +25°C
+85°C
14919 x 10³ hours
9468 x 10³ hours
Derating Graph
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E224736-A25 UL60950-1, 2nd Edition, 2014
CSA/CAN C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety (CB) E224736-A26-CB-1 IEC60950-1, 2nd Edition, 2013
Audio/video, information and communication technology equipment Part
1: safety requirements OFF-4787079973-A-2 IEC62368-1, 2nd Edition, 2014
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2 2011/65/EU
EMI Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter (see suggestions)
EN55032, Class A
EN55032, Class B
continued on next page
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
95
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous
Isolation Voltage (3) I/P to O/P tested for 1 second
rated for 1 minute
6.4kVDC
5.2kVDC
Isolation Capacitance 75pF max.
Isolation Resistance 10G min.
Notes:
Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type
www.recom-power.com REV.: 3/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RK/H6 & RH/H6
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material case
potting
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Package Dimension (LxWxH) 19.6 x 10.2 x 7.0mm
Package Weight 2.7g typ.
continued on next page
L1
C1
C1
C2
C3
C2
L1
+Vin
-Vin
+Vin
-Vin
+Vout
Com
-Vout
+Vout
-Vout
L1
C1
C1
C2
C3
C2
L1
+Vin
-Vin
+Vin
-Vin
+Vout
Com
-Vout
+Vout
-Vout
EMC Filtering Suggestions according to EN55032 Class A and B
Sinlge Output
Dual Output
Component List Class A
Component List Class A
Component List Class B
Component List Class B
Input Voltage C1 C2 L1
all types 10µF
MLCC 100V 1nF 12µH choke
PR4532Z-120M
Input Voltage C1 C2 L1
all types 10µF
MLCC 100V 1nF 22µH choke
PR4532Z-220K
Input Voltage C1 C2 C3 L1
5Vin 22µF MLCC 1nF 1nF 22µH choke
PR4532Z-220K
12, 15, 24Vin 10µF MLCC
Input Voltage C1 C2 L1
5, 12Vin 10µF MLCC -5.6µH choke
PR4532Z-5R6M
15, 24Vin 100pF
www.recom-power.com REV.: 3/2018 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RK/H6 & RH/H6
Series
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 9.3 x 16.5mm
Packaging Quantity 25pcs
Storage Temperature Range -55°C to +125°C
Dimension Drawing (mm)
Recommended Footprint Details
Bottom View
0.5
1.27
10.2
0.5+0.10/-0.05 0.25±0.05
7.05
19.65
embossed Logo
6 x 2.54 =15.24
4 x 2.54 = 9.65
2.00
12 567
2.54
2.54
4.10
Bottom View
1 2 5 7
Marking
Top View
12 567
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
5 -Vout -Vout
6 No Pin Com
7 +Vout +Vout
Tolerance: xx.x= ±0.50mm
xx.xx= ±0.25mm