MEDER electronic
158
www.meder.com
High Voltage Reed Relays
for PCB Mounting
RELAY DATA
HE Series
All Data at 20° C Switch Model →
Contact Form →
Switch 69
Form A / B
Switch 83
Form A / B
Switch 16
Form A
Contact Ratings Conditions Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
Switching Power Any DC combination of V & A not
to exceed their individual max.‘s 50 50 250 W
Switching Voltage DC or peak AC 10 7.5 250
DC/AC kV
Switching Current DC or peak AC 3.0 3.0 1.5 A
Carry Current DC or peak AC 5.0 5.0 1.5 A
Static Contact Resistance w/ 0.5 V & 10mA 150 150 80 mΩ
Insulation Resistance
100 volts applied
Across Contacts
Contacts - Coil
1010
1012
1010
1012
1010
1012 Ω
Breakdown Voltage across
Contact Voltage applied for 60 sec. min. 15
10
10
10
0.8
6kVDC
Operate Time incl. Bounce Measured w/ nominal voltage 3.0 3.0 4 ms
Release Time Measured w/ no coil suppression 1.5 1.5 0.2 ms
Capacitance at 10 kHz cross contact 0.8
8
0.8
5.0
0.8
5.0 pF
Life Expectancies
Switching 5 V - 10 mA DC only & <10 pF stray cap. 50 50 106
Cycles
For other load requirements, see the life test section on P. 120.
Environmental Data
Shock Resistance 1/2 sinus wave duration 11 ms 30 30 30 g
Vibration Resistance From 10 - 2000 Hz 10 10 10 g
Ambient Temperature 10°C/ minute max. allowable -20 70 -20 70 -20 70 oC
Stock Temperature 10°C/ minute max. allowable -35 105 -35 105 -35 105 oC
Soldering Temperature 5 sec. 260 260 260 oC