Notes:
1. Proper circuit protection required when operating with a DC input voltage. 2. Regulation and ripple may deviate from the spec at -20°C start up.
GL20, GL40 GL50 GL60 GL250
Input
Input
Voltage 1
85 - 264 Vac;
120 - 300 Vdc
90 - 264 Vac
127 - 300 Vdc
85 - 264 Vac
120 - 300 Vdc 85 - 264 Vac; 120 - 300 Vdc
Frequency 47-63 Hz , 400± 40 Hz 47-63 Hz
Inrush
Current
GL20: <15A peak
@ 115 Vac; <30A peak @ 230 Vac, cold
start @ 25°C.
GL40: <18A peak
@ 115 Vac; <36A peak @ 230 Vac, cold
start @ 25°C
<60A peak
@ 230 Vac,
cold start @ 25°C
<18A peak
@ 115 Vac,
<36 A peak
@ 230 Vac,
cold start @ 25°C
GL250:
20 A max.,
cold start @ 25°C.
Efficiency 70% typical
at full load
80% - 85%
typical
at full load
70% typical
at full load 75% typical at full load
EMI/RFI FCC Class B ; CISPR 22 Class B ;
EN55022 Class B
Output
Power Refer to the selection table
Adjustment
Range on
Main Output
-5, +10%
minimum
±20% minimum for single output only
models -5, +10% minimum 2:1 wide ratio
Hold-up
Time 20 ms @ full load, 115 Vac nominal line 10/20 ms 115/230 Vac Input line 20 ms @ full load, 115 Vac nominal line 20 ms @ full load, 115 Vac nominal line
Overload Short circuit protection on all outputs.
Primary overload protection
Overvoltage
Protection
5 V output; 5.7 to
6.7 Vdc. Other
outputs 10% to
25% above
nominal output
30-50% above nominal output 5 V output; 5.7 - 6.7 Vdc. Other outputs
10% to 25% above nominal output
5 V output: 5.7
to 6.7 Vdc.
Other outputs 10% to 25% above
nominal output
Remote Sense
Compensates for 0.5 V lead drop
minimum; Will operate without remote
sense connected, Reverse connection
protected
General
Temperature 2Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Electro-
magnetic
Susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing up to 95% RH
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
(2 G peak 8 Hz to 500 Hz for GL500)
MTBF >550,000 hours demonstrated at full load and 25°C ambient conditions
Safety EN60950, cRUus: UL/CSA 60950 E132002, CE Mark (LVD)
Specifications
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
164