GL Series: Single & Multi Output Switchers
The new GL series provides a broad range of AC/DC power
supply solutions that covers power ratings from 25 watts to
250 watts for use in various industrial applications requiring
standard footprint size and very high reliability.
These low-prole AC/DC switchers offer universal input
voltage with no switches or jumpers, ideal for higher volume
worldwide applications.
All models feature:
• Industry standard footprints
• Universal input
• Full power to 50°C
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Built-in EMI Filtering
• Extensive safety approvals
• Derated operation to 70°C
±2% regulation on main output
• 250 VA size enclosed
• Two year limited warranty
Many models feature:
• EN61000-3-2 Compliance
• Supervisory outputs (5 V/12 V)
• Wide-adjustable oating 4th output
• Single wire current share
• Remote Sense
• Adjustable main output
• Power Fail and DC Good signals
• Wide-adjustable on single output models
Certifications and Compliances
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
Recognized Component, ITE
- UL 60950-1
Certied, ITE
- CSA C22.2 CSA 60950-1
- IEC60950-1
Cover Options
• Cover options can be ordered separately. They are
designed to simplify mechanical integration of the
power supplies into systems and add an extra measure
of electrical safety for service personnel.
Cover and Bracket Options
Catalog Number Description
GLX40 Enclosure kit for the GL20 and GL40
GLX250-CEF Cover end fan kit for the GL250
GLX250-CF Cover with top fan kit for the GL250/350
E137632
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
163
Notes:
1. Proper circuit protection required when operating with a DC input voltage. 2. Regulation and ripple may deviate from the spec at -20°C start up.
GL20, GL40 GL50 GL60 GL250
Input
Input
Voltage 1
85 - 264 Vac;
120 - 300 Vdc
90 - 264 Vac
127 - 300 Vdc
85 - 264 Vac
120 - 300 Vdc 85 - 264 Vac; 120 - 300 Vdc
Frequency 47-63 Hz , 400± 40 Hz 47-63 Hz
Inrush
Current
GL20: <15A peak
@ 115 Vac; <30A peak @ 230 Vac, cold
start @ 25°C.
GL40: <18A peak
@ 115 Vac; <36A peak @ 230 Vac, cold
start @ 25°C
<60A peak
@ 230 Vac,
cold start @ 25°C
<18A peak
@ 115 Vac,
<36 A peak
@ 230 Vac,
cold start @ 25°C
GL250:
20 A max.,
cold start @ 25°C.
Efficiency 70% typical
at full load
80% - 85%
typical
at full load
70% typical
at full load 75% typical at full load
EMI/RFI FCC Class B ; CISPR 22 Class B ;
EN55022 Class B
Output
Power Refer to the selection table
Adjustment
Range on
Main Output
-5, +10%
minimum
±20% minimum for single output only
models -5, +10% minimum 2:1 wide ratio
Hold-up
Time 20 ms @ full load, 115 Vac nominal line 10/20 ms 115/230 Vac Input line 20 ms @ full load, 115 Vac nominal line 20 ms @ full load, 115 Vac nominal line
Overload Short circuit protection on all outputs.
Primary overload protection
Overvoltage
Protection
5 V output; 5.7 to
6.7 Vdc. Other
outputs 10% to
25% above
nominal output
30-50% above nominal output 5 V output; 5.7 - 6.7 Vdc. Other outputs
10% to 25% above nominal output
5 V output: 5.7
to 6.7 Vdc.
Other outputs 10% to 25% above
nominal output
Remote Sense
Compensates for 0.5 V lead drop
minimum; Will operate without remote
sense connected, Reverse connection
protected
General
Temperature 2Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Electro-
magnetic
Susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing up to 95% RH
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
(2 G peak 8 Hz to 500 Hz for GL500)
MTBF >550,000 hours demonstrated at full load and 25°C ambient conditions
Safety EN60950, cRUus: UL/CSA 60950 E132002, CE Mark (LVD)
Specifications
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
164
Catalog
Number Output 1 Output 2 Output 3 Output 4 Case 3Pin
Assignments 3
Mating
Connectors 3
GL20
[40 W] 25 W
GLS22 5 V @ 5 A [8 A] 4- - -
1
1A
1B
GLT22 5 V @ 3 A [4 A] 512 V @ 1.5 A [2 A] 5-12 V @ 0.5 A [0.7 A] - 2A
GL40
[55 W] 40 W 1
[40 W] 25 W 2
GLS42 4 5 V @ 8 A [11 A] 4- - -
1
3A
1B
GLS43 4 12 V @ 3.3 A [4.5] 4- - -
GLT42 45 V @ 4 A [5 A] 512 V @ 2 A [2.5 A] 5-12 V @ 0.5 A [0.7 A] -
4A
GLT45 4 5 V @ 4 A [5 A] 515 V @ 2 A [2.5 A] 5-15 V @ 0.5 A [0.7 A] -
GL50
[50 W] 50 W GLT54 45 V @ 8 A 5 24 V @ 1.5 A 512 V @ 0.5 A - 2 5A 2B
GL50
[60 W] 60 W GLS55 424 V @ 2.5 A 4- - - 3 6A 2B
GL60
[80 W] 60 W 1
[60 W] 40 W 2
GLS63 412 V @ 5 A [6.7 A] 4- - -
4 7A 3B
GLS64 415 V @ 4 A [5.3 A] 4- - -
GL250
[250 W] 6 7
GLS253-C 12 V (6-12 V) @ [21 A] - - -
5 8A
4B
GLS255-C 24 V (24-48) @ [10.4 A] - - -
GLQ252-C 5 V @ [35 A] 712 V @ [10 A] -12 V @ [6 A] ±5-25 V @ [6 A] 4
6 9A
GLQ253-C 5 V @ [35 A] 715 V @ [10 A] -15 V @ [6A] ±5-25 V @ [6 A] 4
Selection Table
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Refer to GL Series Dimensions and the sections that follow
4. Floating output
5. Approximate minimum loading: 10%
6. Optional fan cover, See Table 1
7. Optional end fan cover, See Table 1
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
165
GL Series Dimensions
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated.
Case 1
(Weight: 0.5 lbs/0.23 kg approx.)
Case 2
(Weight: 0.45 lbs/0.20 kg approx.)
Case 3
(Weight: 0.41 lbs/0.18 kg approx.)
Case 4
(Weight: 0.75 lbs/0.34 kg approx.)
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
166
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are at factory settings.
4. To enable normally closed remote inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
5.0 (127.0) 2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
3
1
12345678
3 2 1
5
 

 1
 .
4

632 (4 )
5.46
(138.6)
8.52
(216.4)
3 (4 )
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14) 1.30
(33.0)

()

 

()

 
10.32
(262.0)
7

 
10.0
10.0
3
632 
(2 )
3 10.0
632 
(2 )
.24 (6.1)
632 (2 )
 
632 (3 )
Case 5
(Weight: 2.6 lbs/1.19 kg approx.)
Case 6
(Weight: 3.1 lbs/1.41 kg approx.)
5.0 (127.0) 2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK3
SK1
12345678
3 2 1
SK5
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK4
FAN
#6-32 UNC (8 places)
5.46
(138.6)
8.52
(216.4)
M3 (8 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14) 1.30
(33.0)
Optional
(-CF)
Cover
with Fan
Optional
(-CEF)
Cover
with fans
10.32
(262.0)
SK7
FAN
AC Inlet
10.0
10.0
10.0
M3
#6-32 UNC (2 places)
#6-32 UNC
(2 places)
#6-32 (2 places)
M3 (2 places)
4th O/P ADJ.
.24 (6.1)
6-32 (2 places)
Main Output
6-32 (3 places)
SK2
6 5 4 3 2 1
M3
(6 places)
M3
GL Series Dimensions (continued)
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
167
6A
7A
Connector GLS55
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +24 V
PIN 2 +24 V
PIN 3 Common
PIN 4 Common
PIN 5 -Sense
PIN 6 +Sense
Connector GLS63 GLS64
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +12 V +15 V
PIN 2 +12 V +15 V
PIN 3 +12 V +15 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
2A
3A
4A
Connector GLS22
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLT22
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLS42 GLS43
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V
PIN 2 +5 V +12 V
PIN 3 +5 V +12 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLT54
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 Common
PIN 4 Common
PIN 5 +12 V
PIN 6 +24 V
GL Series Pin Assignments
Connector GLT42
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V
SK201 PIN 1 +Sense
PIN 2 -Sense
1A 5A
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
168
GL Series Pin Assignments (continued)
Connector GLS250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O)
PIN 4 Remote Inhibit (N.C)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 -Fan’s power source
(12 V @ 500 mA)
SK5
PIN 1 +Supervisory output supply (5 V @ 100 mA)
PIN 2 -Supervisory output supply
(5 V @ 100 mA)
SK7
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 +Fan’s power source
(12 V @ 500 mA)
Connector GLQ250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK2
PIN 1 +12 / 15 V
PIN 2 Common
PIN 3 Common
PIN 4 -12 / 15 V
PIN 5 5-25 V RET Float
PIN 6 5-25 V Float
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O.)
PIN 4 Remote Inhibit (N.C.)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 +Fan’s power source
(12 V @ 500 mA)
SK5
PIN 1 +Supervisory output supply
(5 V @ 100 mA)
PIN 2 -Supervisory output supply
(5 V @ 100 mA)
SK7
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 +Fan’s power source
(12 V @ 500 mA)
8A 9A
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
169
1B 2B
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-52-0113
(-0111 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
(-0111 for medical)
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0123
(-0114 for medical)
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
GL Series Mating Connectors
3B
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-58-0111
(-0113 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-58-0113
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0113
4B
Connector Kit #70-841-005 includes the
following:
SK3 Molex 22-01-1084; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK7 Molex: 22-01-3027 PINS: 08-50-0114
Power Supplies
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© January 2017
170
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Sola/Hevi-Duty:
GLT22 GLT23 GLT24 GLT25 GLS43 GLT42 GLT43 GLT44 GLT45 GLT46 GLT52 GLT53 GLT54 GLS53I
GLS55 GLS58 GLT62 GLT63 GLT64 GLT65 GLS115 GLS123 GLS152 GLS172 GLS173 GLS175 GLQ172
GLQ252-C GLQ253-C GLS355-C GLS503-CF GLT42-M GLT45-M GLT52-M GLT53-M GLT54-M GLS63-M
GLS64-M GLT62-M GLT63-M GLS505-M-CF GLS103-M GLS203-M GLX110-B GLX110-C GLX120 GLX140-C
GLX140-CF GLX17Q-C GLX250-C GLX40 GLX50 GLX60 70841005 70841006 70841008 70841009 70841010
70841012 70841015 70841016 70841017 70841020 70841024 GLX200