DC Axial Fans
X.X
Motor Protection:
Auto Restart/Polarity Protection
Insulation Resistance:
10MΩoroverwithaDC500VMegger
Dielectric Withstand Voltage:AC700V1s
Allowable Ambient Temperature Range:
-10°C~+70°C(B50~B80)(Operating)
-10°C~+60°C(B90)(Operating)
-40°C~+70°C(Storage)
Material
Casing :Plastic(Black)94V-0
Impeller :Plastic(Black)94V-0
Bearing :BallBearing
Lead Wire
:UL1007,AWG24,+Red,-Black
General Specications
Panel Cut-outs
Characteristic Curves
Expected Life
Failure Rate: 10%
25°C 80,000Hours(E00)
Units: inch
(mm)
Outline
ROTATION
0.177
8F4.5
±
0.3
1.97
(50.0
±
0.3)
2.36
(60.0
±
1.0)
2.36
(60.0
±
1.0)
1.97
(50.0
±
0.3)
7.78
min (200)
1.49
(38.0
±
0.5)
NAME
PLATE
.157
(4.0
±
0.3)
.157
(4.0
±
0.3)
AIR
LOT NO.
.2.48
(F63)
2.52
(F64)
2.28
(58.0)
1.97
(50.0)
2.28
(58.0)
1.97
(50.0)
OUTLET SIDEINLET SIDE
.177
(4F4.5).177
(4F4.5)
2.28
(58.0)
1.97
(50.0)
2.28
(58.0)
1.97
(50.0)
Air Flow
Speed
P-Q Curve
Speed Curve
Static Pressure
Ps
(Pa)
(m3/min)
CFM
In H2O
0.60
1.40
1.80
2.20
0.20
1.00
0
50
100
150
200
250
300
350
400
450
500
550
600
0
1250
2500
3750
5000
6250
7500
8750
10000
11250
12500
13750
15000
0.0 0.5 1.0 1.5 2.0
B80
B90
B70
B80
B90
B70
0 35 71
Rated Operating Current Input Speed Max. Max.Static Noise Mass
MODEL Voltage Voltage Power AirFlow Pressure
Product (V) (V) (A)*1 (W)*1 (min-1)*1 CFM*1 (m3/min)*1 inH2O (Pa)*1 (dB)*1 (g)
No.
2415RL-04W-B70- EXX 12 7~13.8 0.77 9.2 10000 53.0 1.50 1.35 310 56.0 125
2415RL-04W-B80- EXX 12 7~13.8 1.00 12.0 11000 59.0 1.67 1.65 380 58.0 125
2415RL-04W-B90- EXX 12 7~13.2 1.40 16.8 12500 68.1 1.93 2.04 480 61.0 125
Rotation:Clockwise AirowOutlet:AirOutOverStruts *1:AverageValuesinFreeAir
2415RL(60 X 38L)