* 3 Watt in a SIP4 package * 1kVDC/1s, 2kVDC/1s or 3kVDC/1s isolation * Efficiency up to 90% * -40C to +100C operating temperature range * IEC/EN/UL60950 certified * CB Report * Industry standard pinout Features Unregulated Converters Description The RI3 series has been specifically designed for applications where board space is at a premium since these 3 Watt converters have the same foot print as the RI series 2 Watt converters. With efficiencies up to 90%, the full output power is available over the operating temperature range -40C to +85C and the converters can be used in ambient temperatures of up to 100C with derating. The wide selection of input voltage and output voltage options plus an I/O-Isolation of 1kVDC, 2kVDC or 3kVDC makes these converters suitable for many industrial applications. DC/DC Converter RI3 3 Watt SIP4 Single Output Selection Guide Part Number Input Output Output Efficiency max. Capacitive Voltage Voltage Current typ. @ full load Load (1) [VDC][VDC] [mA] [%] [F] RI3-0505S 5 5 600 83 2200 RI3-0509S 5 9 33386 1200 RI3-0512S 5 12 25087 1000 RI3-0515S 5 15 20088 820 RI3-1205S 12 5 60085 2000 RI3-1209S 12 9 33388 1200 RI3-1212S 12 12 25089 1000 RI3-1215S 12 15 20089 820 RI3-1505S 15 5 60085 2000 RI3-1509S 15 9 33388 1200 RI3-1512S 15 12 25088 1000 RI3-1515S 15 15 20088 820 RI3-2405S 24 5 60086 2000 RI3-2409S 24 9 33389 1200 RI3-2412S 24 12 25090 1000 RI3-2415S 24 15 20090 820 E224736 UL60950-1 certified CAN/CSA-C22.2 No 60950-1 certified EN60950-1 certified IEC60950-1 certified EN55032 compliant CB report Notes: Note1: Max. capacitive load is tested at nominal input and constant resistive load Model Numbering RI3-__ __ _/_ Input Voltage Output Voltage Isolation (2) Single Notes: Note2: add suffix "/H2" for 2kVDC/1second or "/H3" for 3kVDC/1second isolation without suffix standard 1kVDC/1second isolation Ordering Examples: RI3-1212S = 12VDC Input Voltage, 12VDC Output Voltage, Single Output, 1kVDC/1s isolation RI3-2405S/H2 = 24VDC Input Voltage, 5VDC Output Voltage, Single Output, 2kVDC/1s isolation RI3-0505S/H3 = 5VDC Input Voltage, 5VDC Output Voltage, Single Output, 3kVDC/1s isolation www.recom-power.com REV.: 3/2019 ECO-1 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition 5VDC 12VDC nom. Vin= 15VDC 24VDC Input Voltage Range Internal Operating Frequency Minimum Load Output Ripple and Noise (3) Min. Typ. Max. 4.5VDC 10.8VDC 13.5VDC 21.6VDC 5VDC 12VDC 15VDC 24VDC 5.5VDC 13.2VDC 16.5VDC 26.4VDC 20kHz 40kHz 0% 20MHz BW 50mVp-p 100mVp-p Notes: Note3: Measurements are made with a 100nF MLCC across output (low ESR) Efficiency vs. Load RI3-12xxS 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RI3-05xxS 60 50 40 30 10 0 10 20 30 40 50 60 70 80 90 40 10 0 100 80 80 70 70 60 50 40 30 20 10 50 60 40 50 60 70 80 90 70 80 100 50 40 2405 2409 2412 2415 10 100 90 60 20 Output Load [%] www.recom-power.com 40 30 1505 1509 1512 1515 30 30 RI3-24xxS 90 20 20 RI3-15xxS 100 10 10 Output Load [%] 90 0 0 Output Load [%] 100 0 1205 1209 1212 1215 20 Efficiency [%] Efficiency [%] 0 50 30 0505 0509 0512 0515 20 60 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REV.: 3/2019 ECO-2 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) REGULATIONS Parameter Condition Output Accuracy 5Vout all other Line Regulation low line to high line Load Regulation (4) Values 3.0% min. / 4.0% typ. 2.0% min. / 3.0% typ. 1.2% of 1.0% Vin typ. 5Vout all other 10% to 100% load 8.0% typ. / 10.0% max. 6.0% typ. / 10.0% max. Notes: Note4: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load RI3-xx05S RI3-xx09S 30 30 0505 1205 1505 2405 Deviation [%] 20 15 20 10 5 15 10 5 0 0 -5 -5 -10 0 10 20 30 40 50 60 70 80 90 0509 1209 1509 2409 25 Deviation [%] 25 -10 100 0 10 20 30 Output Load [%] 40 RI3-xx12S 70 80 90 100 30 0512 1212 1512 2412 20 15 20 10 5 15 10 5 0 0 -5 -5 0 10 20 30 40 50 60 70 80 90 0515 1215 1515 2415 25 Deviation [%] 25 Deviation [%] 60 RI3-xx15S 30 -10 50 Output Load [%] -10 100 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Isolation Voltage Condition tested for 1 second standard without suffix with suffix "/H2" with suffix "/H3" Isolation Capacitance 37pF typ. / 130pF max. Isolation Resistance www.recom-power.com Value 1kVDC 2kVDC 3kVDC 10G min. REV.: 3/2019 ECO-3 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @ natural convection 0.1m/s (see graph) -40C to +85C Maximum Case Temperature +115C Operating Humidity non-condensing 5% - 95% RH max. Vibration MIL-STD-202G MTBF 4395 x 103 hours 1740 x 10 hours +25C +85C according to MIL-HDBK-217F, G.B. Derating Graph (@ Chamber and natural convection 0.1m/s) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 Ambient Temperature [C] 85 SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard IEC60950-1:2005, 2nd Edition + AM2:2013 EN60950-1, 2nd Edition, 2013 Information Technology Equipment - General Requirements for Safety (CB Scheme) E224736-A31-CB-1 Information Technology Equipment - General Requirements for Safety E224736-A32-UL UL60950-1, 2nd Edition, 2014 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014 EAC RU-AT.49.09571 TP TC 004/2011 RoHS 2+ RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Electromagnetic compatibility of multimedia equipment Emission requirements Standard / Criterion with external filter (see filter suggestion below) EN55032, Class B EN55032, Class A EMC Filter Suggestion according to EN55032 C3 L1 +Vin C1 -Vin +Vin +Vout -Vin -Vout +Vout C2 -Vout C4 continued on next page www.recom-power.com REV.: 3/2019 ECO-4 RI3 DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) Component List Class A MODEL Component List Class B C1 L1 C2 RI3-0505S MODEL 22F, 16V MLCC RI3-2405S N/A N/A RI3-0505S RI3-2405S 10F, 100V MLCC RI3-2412S C1 RI3-2415S L1 C3 (safety) C4 (safety) 10F 5.6H choke 100V MLCC RLS-567 470pF 330pF Notes: Note5: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting non-conductive plastic, (UL94 V-0) silicone, (UL94 V-0) Dimension (LxWxH) 11.5 x 7.6 x 10.2mm Weight 2.2g typ. Dimension Drawing (mm) Pinning information Pin # 1 2 3 4 embossed logo 7.6 Tolerance: xx.x= 0.5mm xx.xx= 0.25mm Marking 0.51 10.2 11.5 Single -Vin +Vin -Vout +Vout 1 2 3 4 Bottom View 0.85O 2.54 Recommended Footprint Standard H3 Version 0.85O +0.15/-0 2.54 7.62 1.00 Recommended Footprint Standard H2 Version 1.00 O +0.15/-0 Top View 1.27 2.00 0.250.05 4.10 0.75+0.10/-0.05 1.80 solder pad for /H3 models Top View 1 2 3 4 1 2 3 4 2.54 2.54 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.5 x 9.0mm Packaging Quantity tube Storage Temperature Range Storage Humidity 42pcs -55C to +125C non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 3/2019 ECO-5