LOW LEVEL MEASURE & SOURCE
www.keithley.com
1.888.KEITHLEY (U.S. only)
A Greater Measure of Confidence
Cost-effective low current
measurement solution
10fA resolution
5½-digit resolution
<200µV burden voltage
Up to 1000 readings/second
Built-in Model 485 emulation
mode
IEEE-488 and RS-232 interfaces
Analog output
The 5½-digit Model 6485 Picoammeter combines
Keithley’s expertise in sensitive current measure-
ment instrumentation with enhanced speed and
a robust design. With eight current measurement
ranges and high speed autoranging, this cost-
effective instrument can measure currents from 20fA
to 20mA, taking measurements at speeds up to 1000
readings per second.
The Model 6485s 10fA resolution and superior
sensitivity make it well suited for characterizing low
current phenomena, while its 20mA range lets it
measure currents high enough for applications such
as measuring 4-20mA sensor loops.
Although it employs the latest current measurement
technology, it is significantly less expensive than
other instruments that perform similar functions,
such as optical power meters, competitive pico-
ammeters, or user-designed solutions. With a price that’s comparable to a general purpose DMM,
the Model 6485 makes picoamp-level measurements affordable for virtually any laboratory or
production floor.
Low Voltage Burden and Higher Accuracy
While DMMs typically employ shunt ammeter circuitry to measure current, the Model 6485 is a feed-
back picoammeter. This design reduces voltage burden by several orders of magnitude, resulting in a
voltage burden of less than 200µV on the lower measurement ranges. The low voltage burden makes
the Model 6485 function much more like an ideal ammeter than a DMM, so it can make current
measurements with high accuracy, even in circuits with
very low source voltages.
Successor to the Model 485
The Model 6485 builds on the strengths of one of
Keithley’s most popular picoammeters, the Model 485,
offering an additional 20mA measurement range, as well
as much higher measurement speeds. With a top speed
of up to 1000 readings per second, the Model 6485 is
the fastest picoammeter Keithley has ever made. It offers ten times greater resolution than the Model
485 on every range. A time-stamped 2500-reading data buffer provides minimum, maximum, and
standard deviation statistics. A built-in emulation mode simplifies upgrading existing applications
originally configured with a Model 485. This emulation mode makes it possible to control the Model
6485 with any custom code written to control the Model 485. Refer to the comparison table for
additional information.
Model 485 Model 6485
Current Ranges 2nA–2mA 2nA–20mA
Voltage Burden 200µV 200µV (1mV on
20mA range)
Reading Rate 3/s 1000/s
Digits
Analog Output Yes Yes
Battery Option Yes No
Storage Buffer 100 points 2500 points
When do you need a picoammeter?
Measuring low DC currents often demands a lot more than a digital
multimeter (DMM) can deliver. Generally, DMMs lack the sensitivity required
to measure currents less than 100nA. Even at higher currents, a DMMs
input voltage drop (voltage burden) of hundreds of millivolts can make
accurate current measurements impossible. Electrometers can measure
low currents very accurately, but the circuitry needed to measure extremely
low currents, combined with functions like voltage, resistance, and charge
measurement, can increase an electrometers cost signifi cantly. The Model
6485 Picoammeter combines the economy and ease of use of a DMM with
low current sensitivity near that of an electrometer.
6485
Picoammeter
Measures low currents quickly, accurately, and economically
Measures low currents quickly, accurately, and economically
LOW LEVEL MEASURE & SOURCE
A Greater Measure of Confidence
www.keithley.com
1.888.KEITHLEY (U.S. only)
Features that Expand Test and Measurement Flexibility
Scaled voltage analog output. This output allows the Model 6485 to transmit measurement
results to devices like DMMs, data acquisition boards, oscilloscopes, or strip chart recorders.
220V overload protection. This high overload protection and a robust design let the Model 6485
withstand abusive overflows.
One-touch front panel design. Functions can be configured easily with the push of a button,
without complicated function menus.
Built-in Trigger Link interface. The Trigger Link interface simplifies synchronizing the Model
6485 with other instruments and voltage sources. This interface combines six independent
selectable trigger lines on a single connector for simple, direct control over all instruments
in a system.
RS-232 and IEEE-488 interfaces. These interfaces make it easy to integrate the Model 6485 into
automated test and measurement systems.
Display on/off switch. For research on light-sensitive components, such as measuring the dark
currents of photodiodes, the front panel display can be switched off to avoid introducing light that
could significantly reduce the accuracy of the results.
REL and LOG functions. The Model 6485 can make relative readings with respect to a baseline
value or display the logarithm of the absolute value of the measured current.
Resistance calculations. The Model 6485 can calculate resistance by dividing an externally
sourced voltage value by the measured current.
Rear panel BNC inputs. Inexpensive, easy-to-use BNC cables can be employed, rather than more
expensive triax cables.
APPLICATIONS
Beam monitoring and radiation
monitoring
Leakage current testing in
insulators, switches, relays, and
other components
SEM beam current
measurements
Galvanic coupling
measurements
Optoelectronic device testing
and characterization
Optical fiber alignment
Circuit test and analysis in
DCLF circuits
Sensor characterization
I-V measurements of
semiconductors and other
devices
Nanoelectronic device
characterization
Capacitor leakage
Teaching labs
Ordering Information
6485 Picoammeter
Accessories Supplied
CAP-18 Protective Shield/
Cap (2-lug)
4801 Low Noise BNC Input
Cable, 1.2m (4 ft)
ACCESSORIES AVAILABLE
CABLES
4802-10 Low Noise BNC Input Cable, 3m (10 ft)
4803 Low Noise Cable Kit
7007-1 Shielded IEEE-488 Cable, 1m (3.3 ft)
7007-2 Shielded IEEE-488 Cable, 2m (6.6 ft)
7007-4 Shielded IEEE-488 Cable, 4m (13.1 ft)
7009-5 RS-232 Cable
7754-3 BNC to Alligator Cable, 0.9m (3 ft)
8607 Banana Cable set for Analog Output
8501-1 Trigger Link Cable with Male Micro-DIN Connectors at
each End, 1m (3.3 ft)
8501-2 Trigger Link Cable with Male Micro-DIN Connectors at
each End, 2m (6.6 ft)
8503 DIN-to-BNC Trigger Cable
ADAPTERS
CS-565 BNC Barrel
7078-TRX-BNC Female BNC to 3-Slot Male Triax for connecting
BNC cable into triax fixture
RACK MOUNT KITS
4288-1 Single Fixed Rack Mounting Kit
4288-2 Dual Fixed Rack Mounting Kit
GPIB INTERFACES
KPCI-488LPA IEEE-488 Interface/Controller for the PCI Bus
KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter
SERVICES AVAILABLE
6485-3Y-EW 1-year factory warranty extended to 3 years from
date of shipment
C/6485-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3
years of purchase*
*Not available in all countries
6485
Picoammeter
Measures low currents quickly, accurately, and economically
Measures low currents quickly, accurately, and economically
LOW LEVEL MEASURE & SOURCE
www.keithley.com
1.888.KEITHLEY (U.S. only)
A Greater Measure of Confidence
GENERAL
INPUT CONNECTOR: BNC on rear panel.
DISPLAY: 12 character vacuum fluorescent.
RANGING: Automatic or manual.
OVERRANGE INDICATION: Display reads “OVRFLOW.
CONVERSION TIME: Selectable 0.01 PLC to 60 PLC (50 PLC under 50Hz operation).
(Adjustable from 200µs to 1s)
READING RATE:
To internal buffer: 1000 readings/second1
To IEEE-488 bus: 900 readings/second1, 2
Notes:
1. 0.01 PLC, digital filters off, front panel off, auto zero off.
2. Binary transfer mode. IEEE-488.1.
BUFFER: Stores up to 2500 readings.
PROGRAMS: Provide front panel access to IEEE address, choice of engineering units or
scientific notation, and digital calibration.
EMC: Conforms with European Union Directive 89/336/EEC, EN61326-1.
SAFETY: Conforms with European Union Directive 73/23/EEC, EN61010-1.
TRIGGER LINE: Available, see manual for usage.
DIGITAL FILTER: Median and averaging (selectable from 2 to 100 readings).
ENVIRONMENT:
Operating: 0°–50°C; relative humidity 70% non-condensing, up to 35°C. Above 35°C,
derate humidity by 3% for each °C.
Storage: –25° to +65°C.
WARM-UP: 1 hour to rated accuracy (see manual for recommended procedure).
POWER: 100120V or 220–240V, 5060Hz, 30VA.
PHYSICAL:
Case Dimensions: 90mm high × 214mm wide × 369mm deep (3
½
in. × 838 in. × 14916 in.).
Working Dimensions: From front of case to rear including power cord and IEEE-488 con-
nector: 394mm (15.5 in).
Net Weight: <2.8 kg (<6.1 lbs).
Shipping Weight: <5 kg (<11 lbs).
IEEE-488 BUS IMPLEMENTATION
MULTILINE COMMANDS: DCL, LLO, SDC, GET, GTL, UNT, UNL, SPE, SPD.
IMPLEMENTATION: SCPI (IEEE-488.2, SCPI-1996.0); DDC (IEEE-488.1).
UNILINE COMMANDS: IFC, REN, EOI, SRQ, ATN.
INTERFACE FUNCTIONS: SH1, AH1, T5, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT1, C0, E1.
PROGRAMMABLE PARAMETERS: Range, Zero Check, Zero Correct, EOI (DDC mode only),
Trigger, Terminator (DDC mode only), Calibration (SCPI mode only), Display Format, SRQ,
REL, Output Format, V-offset Cal.
ADDRESS MODES: TALK ONLY and ADDRESSABLE.
LANGUAGE EMULATION: Keithley Model 485 emulation via DDC mode.
RS-232 IMPLEMENTATION:
Supports: SCPI 1996.0.
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k.
Protocols: Xon/Xoff, 7 or 8 bit ASCII, parity-odd/even/none.
Connector: DB-9 TXD/RXD/GND.
5
½
Digit Accuracy (1 Year) 1Analog
Default ±(% rdg. + offset) Typical Rise Time 3
Range Resolution 18°–2C, 070% RH RMS Noise 2 (10% to 90%)
2 nA 10 fA 0.4 % + 400 fA 20 fA 8 ms
20 nA 100 fA 0.4 % + 1 pA 100 fA 8 ms
200 nA 1 pA 0.2 % + 10 pA 1 pA 500 µs
2 µA 10 pA 0.15% + 100 pA 10 pA 500 µs
20 µA 100 pA 0.1 % + 1 nA 100 pA 500 µs
200 µA 1 nA 0.1 % + 10 nA 1 nA 500 µs
2 mA 10 nA 0.1 % + 100 nA 10 nA 500 µs
20 mA 100 nA 0.1 % + 1 µA 100 nA 500 µs
TEMPERATURE COEFFICIENT: 0°–18°C & 28°–50°C. For each °C, add 0.1 × (% rdg + offset) to
accuracy spec.
INPUT VOLTAGE BURDEN: <200µV on all ranges except <1mV on 20mA range.
MAXIMUM INPUT CAPACITANCE: Stable to 10nF on all nA ranges and 2µA range; 1µF on 20µA
and 200µA ranges, and on mA ranges.
MAXIMUM COMMON MODE VOLTAGE: 42V.
MAXIMUM CONTINUOUS INPUT VOLTAGE: 220 VDC.
ISOLATION (Meter COMMON to chassis): Typically >5×1011W in parallel with <1nF.
NMRR1 (50 or 60Hz): 60dB.
ANALOG OUTPUT: Scaled voltage output (inverting 2V full scale on all ranges) 3% ±2mV, 1kW
impedance.
NOTES
1. At 1 PLC – limited to 60 rdgs/second under this condition.
2. At 6 PLC, 1 standard deviation, 100 readings, filter off, capped input – limited to 10 rdgs/sec under this condition.
3. Measured at analog output with resistive load >100kW.
6485 Picoammeter
Model 6485 specifications
Model 6485 specifications