Document Number: 28712 For technical questions, contact: filmresistors.thinfilmchip@vishay.com www.vishay.com
Revision: 25-Aug-08 5
MCT 0603 HF
High Frequency Flat Chip Resistors Vishay Beyschlag
TESTS AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
EN 60115-1, Generic specification (includes tests)
EN 140 400, Sectional specification (includes schedule for
qualification approval)
EN 140 401-801, Detail specification (includes schedule for
conformance inspection)
The components are approved in accordance with the
European CECC-system, where applicable. The following
table contains only the most important tests. For the full test
schedule refer to the documents listed above. The testing
also covers most of the requirements specified by
EIA/IS-703 and JIS-C-5202.
The tests are carried out in accordance with IEC 60068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower Category Temperature, Upper
Category Temperature; damp heat, long term, 56 days) is
valid.
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
The components are mounted for testing on boards in
accordance with EN 60115-1, 4.31 unless otherwise
specified.
The requirements stated in the Test Procedures and
Requirements table below are based on the required tests
and permitted limits of EN 140 401-801. However, some
additional tests and a number of improvements against those
minimum requirements have been included.
TEST PROCEDURES AND REQUIREMENTS
EN 60115-1
CLAUSE
IEC 60068-2 TEST
METHOD TEST PROCEDURE REQUIREMENTS PERMISSIBLE
CHANGE (ΔR/R)
Stability for product types:
MCT 0603 HF 6.8 Ω to 470 Ω
4.5 - Resistance ± 2 %
4.8.4.2 - Temperature coefficient At 20/- 55/20 °C and
20/125/20 °C± 50 ppm/K
4.25.1 -
Endurance at 70 °C:
Standard operation mode
U= 1.5 h on;
0.5 h off
70 °C; 1000 h ± (0.5 % R+0.05 Ω)
70 °C; 8000 h ± (1 % R+0.05 Ω)
4.25.3 - Endurance at upper
category temperature 125 °C; 1000 h ± (1 % R+0.05 Ω)
4.24 78 (Cab) Damp heat, steady state (40 ± 2) °C; 56 days;
(93 ± 3) % RH ± (1 % R+0.05 Ω)
4.23 Climatic sequence:
4.23.2 2 (Ba) Dry heat UCT; 16 h
4.23.3 30 (Db) Damp heat, cyclic 55 °C; 24 h; > 90 % RH; 1 cycle
4.23.4 1 (Aa) Cold LCT; 2 h
4.23.5 13 (M) Low air pressure 8.5 kPa; 2 h; 25 ± 10 °C
4.23.6 30 (Db) Damp heat, cyclic
55 °C; 5 days;
> 95 % to 100 % RH;
5 cycles
LCT = - 55 °C;
UCT = 125 °C
± (1 % R+0.05 Ω)
- 1 (Aa) Cold - 55 °C; 2 h ± (0.5 % R+0.05Ω)
4.19 14 (Na) Rapid change of
temperature
30 min at LCT and
30 min at UCT;
LCT = - 55 °C;
UCT = 125 °C;
5 cycles
± (0.5 % R+0.05 Ω)
no visible damage
4.13 - Short time overload;
standard operation mode
U= 2.5 x ± (0.5 % R+0.05 Ω)
P70 x R
P70 x R