cui.com
date 08/25/2020
page 1 of 4
SERIES: SWM6-E-USB DESCRIPTION: AC-DC POWER SUPPLY
MODEL output
voltage
output
current
output
power
ripple
and noise1
eciency
level2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
SWM6-5-E-I38 5 1.2 6 100 VI
SWM6-6-E-I38 6 1 6 120 VI
SWM6-9-E-I38 9 0.66 6 180 VI
SWM6-12-E-I38 12 0.5 6 240 VI
Notes: 1.Atfullload,100~240Vacinput,20MHzbandwidthoscilloscope,outputterminatedwithalowESR47μFelectrolyticand0.1μFmultilayercapacitor.
2. CoC Tier 2 compliant.
FEATURES
• up to 6 W power
• EN 60601-1 4th edition
• compact vertical or horizontal mount
• universal input (90~264 Vac)
• single regulated output from 5~12 Vdc
• over voltage and short circuit protections
•DOELevelVI/CoCTier2efficiency
• 2 MOPP compliant
PART NUMBER KEY
Base Number Reserved for Custom
Congurations
SWM6 - XX - E X - I38 - CXX
USBTypeAInlet
Output Voltage
ACInputType:
Europe
Orientation:
H = horizontal
V = vertical
Additional Resources: Product Page
cui.com
date 08/25/2020 page 2 of 4CUI Inc SERIES: SWM6-E-USB DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current at 115 Vac, full load
at 230 Vac, full load
0.6
0.3
A
A
inrush current at 115 Vac, full load, cold start
at 230 Vac, full load, cold start
30
60
A
A
leakage current at 240 Vac, 50 Hz 0.1 mA
no load power consumption at 115/230 Vac, 60/50 Hz 0.075 W
OUTPUT
parameter conditions/description min typ max units
line regulation ±1 %
load regulation ±5 %
start-up time at 100 Vac, to 90% of rated output voltage 3 s
rise time at nominal input voltage, full load, from 10% to
90% of output voltage 50 ms
hold-up time at nominal input voltage, full load 8.3 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection outputshutdown,autorecovery
over current protection outputshutdown,autorecovery 200 %
short circuit protection outputshutdown,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output 4,000 Vac
isolation resistance input to output at 500 Vdc for 3 seconds 50
safetyapprovals medical TUV EN 60601-1
EMI/EMC CE
MTBF asperMIL-HDBK-217F 100,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 85 °C
operatinghumidity non-condensing 10 90 %
storagehumidity non-condensing 5 90 %
altitude 5,000 m
Additional Resources: Product Page
cui.com
date 08/25/2020 page 3 of 4CUI Inc SERIES: SWM6-E-USB DESCRIPTION: AC-DC POWER SUPPLY
MECHANICAL
parameter conditions/description min typ max units
dimensions horizontal models: 55 x 27 x 55
vertical models: 53 x 41 x 46
mm
mm
inlet plug Europe
weight horizontal models
vertical models
60
65
g
g
color black
MECHANICAL DRAWINGS
units: mm
tolerance: ±1 mm
46
Horizontal Models Vertical Models
Additional Resources: Product Page
date 08/25/2020 page 4 of 4CUI Inc SERIES: SWM6-E-USB DESCRIPTION: AC-DC POWER SUPPLY
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1)Thisdevicemaynotcauseharmfulinterference,and
(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
CUIoersaone(1)yearlimitedwarranty.Completewarrantyinformationislistedonourwebsite.
CUIreservestherighttomakechangestotheproductatanytimewithoutnotice.InformationprovidedbyCUIisbelievedtobeaccurateandreliable.However,noresponsibilityis
assumedbyCUIforitsuse,norforanyinfringementsofpatentsorotherrightsofthirdpartieswhichmayresultfromitsuse.
CUIproductsarenotauthorizedorwarrantedforuseascriticalcomponentsinequipmentthatrequiresanextremelyhighlevelofreliability.Acriticalcomponentisanycomponentofa
lifesupportdeviceorsystemwhosefailuretoperformcanbereasonablyexpectedtocausethefailureofthelifesupportdeviceorsystem,ortoaectitssafetyoreectiveness.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax503.612.2383
cui.com
techsupport@cui.com
rev. description date
1.0 initial release 06/27/2017
1.01 companylogoupdated 08/25/2020
Therevisionhistoryprovidedisforinformationalpurposesonlyandisbelievedtobeaccurate.
REVISION HISTORY
Additional Resources: Product Page