https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) (R) Modular bridge for transmitting DeviceNet/SDS/CANopen via Ethernet, modem, and wireless paths. High-quality electrical isolation between the interfaces, DIN-rail mountable, 24 V DC supply. Your advantages CAN data rates of up to 1 Mbps RS-422 data rates of up to 500 kbps High-quality 4-way isolation between all interfaces Can be combined with PSI-MOS FO converters in a modular way thanks to DIN rail connectors All connections can be plugged in using a COMBICON screw terminal block Approved for use in zone 2 Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356464697 Weight per Piece (excluding packing) 280.000 g Custom tariff number 85176200 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 35 mm 12/15/2020Page1/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Technical data Dimensions Height 111 mm Depth 121 mm Ambient conditions Ambient temperature (operation) -20 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 30 % ... 95 % (non-condensing) Degree of protection IP20 Noise immunity EN 61000-6-2 Interfaces Interface 1 CAN interface, in accordance with ISO/IS 11898 for DeviceNet, CAN, CANopen Operating mode Semi-duplex No. of ports 2 (CAN_High / CAN_Low) Connection method COMBICON plug-in screw terminal block File format/coding Bit stuffing, NRZ Transmission medium 2-wire twisted pair, shielded Transmission length 5000 m (Dependent on the data rate and the protocol used) Termination resistor Integrated and ready to be switched 124 , integrated and can be connected Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Serial transmission speed 1000 kbps Interface 2 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 Interface RS-422 Connection method COMBICON plug-in screw terminal block File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length Transmission length 1200 m (Dependent on the data rate) Termination resistor 150 Integrated, cannot be switched Serial transmission speed 500 kbps Digital outputs Output name Relay output 12/15/2020Page2/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Technical data Digital outputs Number of outputs 1 Contact type N/O contact Minimum switching voltage 11 VDC Maximum switching voltage 30 VDC Limiting continuous current 500 mA Power supply Nominal supply voltage 24 VDC Supply voltage range 11 VDC ... 30 VDC (via pluggable COMBICON screw terminal block) Max. current consumption 80 mA Typical current consumption 55 mA (24VDC) General Bit distortion, input 35 % Bit distortion, output < 6.25 % Electrical isolation according to EN 60950 VCC // CAN // RS-422 Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 Net weight 236.3 g Housing material PA 6.6-FR Color green MTBF 765 Years (Telcordia standard, 25C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 169 Years (Telcordia standard, 40C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) MTTF 1053 Years (SN29500 standard, temperature25C, operating cycle21%) 482 Years (SN29500 standard, temperature40C, operating cycle34.25%) 194 Years (SN29500 standard, temperature40C, operating cycle100%) Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Type of test Free fall in acc. with IEC 60068-2-32 Test result 1m Type of test Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 Test result 5g, 10...150 Hz, 2.5 h, in XYZ direction Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27 Test result 15g, 11 ms period, half-sine shock pulse 12/15/2020Page3/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Technical data Standards and Regulations Noise emission EN 55011 Noise immunity EN 61000-6-2 Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard Standards/regulations EN 61000-4-2 Contact discharge 6 kV Standards/regulations EN61000-4-3 Frequency range 80 MHz ... 3 GHz Standards/regulations EN61000-4-4 Comments Criterion B Standards/regulations EN61000-4-5 Signal 1 kV Standards/regulations EN 55011 EN61000-4-6 Designation Air clearances and creepage distances Standards/regulations DINEN50178, DINEN60950 Electrical isolation according to EN 60950 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram Dimensional drawing 121 35 PSI-BRIDGE-DNET CAN COMBICON PSI-BRIDGE-DNET CAN Ord.-No. 23 13 533 T(B) / T+ T(A) 1 T(A) / T- R(B) 4 R(B) R+ R(A) 3 R(A) R- GND 5 GND VCC TD RD 111 T(B) 2 ACT NET A PORT A TERM. ON PORT 6 A /SHD RS-422 connection 12/15/2020Page4/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Schematic diagram Application drawing PSI-BRIDGE-DNET CAN Ord.-No. 23 13 533 RS 422 ETHERNET VCC TD RD B B WIRELESS MODEM ACT NET A PORT A TERM. ON PORT A = Switch on bus terminating resistor Slide switch for termination resistor Schematic diagram Application drawing 1 2 3 4 RS-422 B B 23 22 21 20 19 18 17 16 5 6 7 8 9 10 PSI-BRIDGE-DNET CAN Ord.-No. 23 13 533 VCC TD RD ACT = Switch on bus terminating resistor NET A Connection via RS-422 PORT A TERM. ON PORT 11 12 13 14 15 A Front view RS-422 Ethernet Comserver B Comserver Application drawing RS-422 Application drawing B B RS-422 RS-422 B PSI-WL-RS232-RS485/BT/2DO = Switch on bus terminating resistor Connection via Ethernet = Switch on bus terminating resistor Connection via Bluetooth 12/15/2020Page5/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Application drawing B RS-422 RS-232 RS-232 RS-422 B PSM-ME-RS232/RS485-P = Switch on bus terminating resistor Connection via industrial modem Block diagram USB DC 24 V gn DC 0V 11 Alarm 12 gn gn Bus management DC rd DC Port B RS-422 rd (1) T(A) Port A V+ 5V CAN_High 390 150 SHD 390 CAN_Low V- (2) T(B) (3) R(A) (4) R(B) (5) GND (6) SHD 124 24 V 0 V GND Data Data B A DIN rail connector (T-BUS) Classifications eCl@ss eCl@ss 4.0 27240490 eCl@ss 4.1 27240490 eCl@ss 5.0 27242208 eCl@ss 5.1 27242200 eCl@ss 6.0 27141100 eCl@ss 7.0 27141140 eCl@ss 8.0 27141140 eCl@ss 9.0 27141140 ETIM ETIM 3.0 EC001423 ETIM 4.0 EC001423 ETIM 5.0 EC000489 12/15/2020Page6/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Classifications ETIM ETIM 6.0 EC000489 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121426 UNSPSC 19.0 39121426 Accessories Accessories Data cable by the meter Bus system cable-SAC-5P-920/...-1511504 (R) Bus system cable, CANopen , DeviceNetTM, 4-position, PUR halogen-free, violet RAL 4001, shielded, cable length: Free entry (0.5 ... 400 m) Data plug D-SUB bus connector-SUBCON-PLUS-CAN/90/PG/M12-2902322 D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/90/M12-2902323 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 90. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. 12/15/2020Page7/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Accessories D-SUB bus connector-SUBCON-PLUS-CAN/35/PG/M12-2902324 D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 35. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/35/M12-2902325 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 35. Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN/AX/M12-2902326 D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands (A-coded) under 180 (axial). Bus system: CAN, CANopen(R). Termination resistor via separate M12 terminator. D-SUB bus connector-SUBCON-PLUS-CAN-2744694 D-SUB connector, 9-pos. female connector, two cable entries < 35 to one terminal block row, bus system: CAN, (R) CANopen , SafetyBUS p up to 1 Mbps, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7; screw connection terminal blocks D-SUB bus connector-SUBCON-PLUS-CAN/PG-2708119 (R) D-SUB connector, 9-pos. socket, cable entry < 35, bus system: CAN, CANopen , SafetyBUS p up to 1 Mbps, with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 2, 3, 7, 9; screw terminal blocks 12/15/2020Page8/9 https://www.phoenixcontact.com/us/products/2313533 Interface converters-PSI-BRIDGE-DNET CAN-2313533 Accessories D-SUB bus connector-SUBCON-PLUS-CAN/AX-2306566 D-SUB connector, 9-pos. female connector, axial version with two cable entries, bus system: CAN, CANopen, SafetyBUS p; pin assignment: 2, 3, 7; screw connection terminal blocks DIN rail connector DIN rail bus connectors-ME 17,5 TBUS 1,5/ 5-ST-3,81 GN-2709561 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Power supply Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A Phoenix Contact 2020 (c) - all rights reserved http://www.phoenixcontact.com 12/15/2020Page9/9