Switch Mode Power Supply Model AAD600S H.A.L.T. 600 Watts max output power Power Factor Correction TESTED Highly Accelerated Life Testing Single Output Electrical Specifications Input Voltage: 85-264 VAC, 47-63 Hz Input Current: <6.5A RMS @ 115 VAC @ full load <3.5A RMS @ 230 VAC @ full load 9.0A RMS @ 85 VAC @ full load Inrush Current: <20A, pk @ 110 VAC, active soft start <40A, pk @ 220 VAC, active soft start (Active independant of cold or warm start) Power Factor: >0.99 @ full load @ 230VAC input Harmonic Distortion: Meets IEC1000-3-2 EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15 Class B (conducted) Input Protection: Internal AC line fuse; 250 VAC, 10A Surge Withstand: Meets EN61000-4-4 Level 3 and EN61000-4-5 Level 3 Output Power: Up to 600W continuous Line Regulation: 0.1% Load Regulation: 0.25% PARD: <1% or 250mV 20MHz bandwidth Hold-up Time: >16 ms @ full load Output Polarity: Output is floating Minimum Load: Transient Response: AC Power Fail: TTLLOW logic "0" at least 2 ms before DC output drops 5% (without signal jitter). Open collector. DC OK: Open collector when output voltage is above 95% of rated Overcurrent/Short Circuit: Square current limit; 105-130% of rated Overvoltage Protection: Factory set, 125% 5% cycle AC to reset None Reverse Voltage: Reverse current up to rated outputs 2% for 25% load change @ 1A/s Thermal Protection: Auto off; auto reset upon cool down Output Rise Time: <100 ms (10% to 90%) Efficiency: Up to 92% Remote Sense: Standard MTBF: Current Share: Within 5% Remote On/Off: Ground or TTLLOW = OFF Open or TTLHIGH = ON MIL-STD-HDBK 217E 200,000 hours @ 25C, ground benign, Highly Accelerated Life Testing Available Voltage Outputs* Voltage Codes Voltages (Volts) Continuous Current (Amps) -4 12 42 -5 15 36 -6 24 23 -7 28 20 -8 36 16 48 12.5 -9 * Consult factory for other voltages and OEM quantities. Note: Standard models are shown bold PART # STRUCTURE: MODEL VOLTAGE CODE OPTION CODES (See back) V1 AAD600S X ABC.... Example: Part Number AAD600S-8-CF = 600W Power Factor Corrected, 36V @ 16A with sealed pots and overcurrent foldback mode. CLICK HERE TO SEE THE AAD600S CODE TABLE AND AVAILABLE OPTIONS. Model AAD600S Options (code) DC OK Invert (U) Metric Mounting (M) OR-ing Diodes (O) Droop Current Share (A) Gold Plated Signal Connector (G) Sealed Pots (C) Compliance PF Invert (B) Remote On/Off Invert (S) Overcurrent Hiccup Mode (D) Overcurrent Latch-off Mode (E) Overcurrent Foldback Mode (F) Standby Power (5VDC @ 1A) (P)** EN61000-4-5 Level 3 EN61000-4-2 Level 2 EN61000-3-2 EN61000-4-2 Level 3 (Air Only) EN61000-4-4 Level 3 EN61000-4-11 CISPR 11 and 22 FCC Part 15 Class B (conducted) Physical Specifications **Voltage available as long as AC input is present Dimensions: (HxWxL) 1.59" x 4" x 9" Certifications Operating Temp: 0 to 70C; rated power to 50C derate linearly to 50% at 70C. NRTL*** to UL60950-1, CSA C22.2 60950-1-03 BAUART Certification to EN60950-1 CB Test Report in Accordance with IEC60950-1 CE Declaration to Low Voltage Directive 72/73/EEC Relative Humidity: 5% to 90%, non-condensing Storage: -50 to 85C/20-90% RH Altitude: 6,561' operating; 40,000' storage 1 L N *** Nationally Recognized Test Laboratory (c) Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice. TAMURA CORPORATION OF AMERICA 1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951 (951) 699-1270 / Fax: (951) 676-9482 (800) 472-6624 www.tamuracorp.com FM 32227