Input Voltage: 85-264 VAC, 47-63 Hz
Input Current: <6.5A RMS @ 115 VAC @ full load
<3.5A RMS @ 230 VAC @ full load
9.0A RMS @ 85 VAC @ full load
Inrush Current: <20A, pk @ 110 VAC, active soft start
<40A, pk @ 220 VAC, active soft start
(Active independant of cold or warm start)
Power Factor: >0.99 @ full load @ 230VAC input
Harmonic Distortion: Meets IEC1000-3-2
EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection: Internal AC line fuse; 250 VAC, 10A
Surge Withstand: Meets EN61000-4-4 Level 3
and EN61000-4-5 Level 3
Output Power: Up to 600W continuous
Line Regulation: ± 0.1%
Load Regulation: ±0.25%
PARD: <1% or 250mV
20MHz bandwidth
Hold-up Time: >16 ms @ full load
Output Polarity: Output is floating
Minimum Load: None
Transient Response: 2% for 25% load change @ 1A/µs
Output Rise Time: <100 ms (10% to 90%)
Remote Sense: Standard
Current Share: Within 5%
Remote On/Off: Ground or TTLLOW = OFF
Open or TTLHIGH = ON
AC Power Fail: TTLLOW logic “0” at least 2 ms before DC
output drops 5% (without signal jitter).
Open collector.
DC OK: Open collector when output voltage is above
95% of rated
Overcurrent/Short Circuit: Square current limit; 105-130% of rated
Overvoltage Protection: Factory set, 125% ±5%
cycle AC to reset
Reverse Voltage: Reverse current up to rated outputs
Thermal Protection: Auto off; auto reset upon cool down
Efficiency: Up to 92%
MTBF: MIL-STD-HDBK 217E
200,000 hours @ 25°C, ground benign,
Highly Accelerated Life Testing
Electrical Specifications
Continuous
Voltage Voltages Current
Codes (Volts) (Amps)
-4 12 42
-5 15 36
-6 24 23
-7 28 20
-8 36 16
-9 48 12.5
* Consult factory for other voltages and OEM quantities.
Note: Standard models are shown bold
Available Voltage Outputs*
AAD600S
Model
600 Wattsmax output power
Power Factor Correction
Single Output
Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES (See back)
- V1 -
AAD600S - X - ABC....
Example: Part Number AAD600S-8-CF = 600W Power Factor Corrected, 36V @ 16A with sealed pots and overcurrent foldback
mode.
CLICK HERE TO SEE THE AAD600S CODE TABLE AND AVAILABLE OPTIONS.
Physical Specifications
Dimensions: (HxWxL) 1.59" x 4" x 9"
Operating Temp: 0 to 70°C; rated power to 50°C
derate linearly to 50% at 70°C.
Relative Humidity: 5% to 90%, non-condensing
Storage: -50 to 85°C/20-90% RH
Altitude: 6,561' operating;
40,000' storage
Options (code)
DC OK Invert (U) PF Invert (B)
Metric Mounting (M) Remote On/Off Invert (S)
OR-ing Diodes (O) Overcurrent Hiccup Mode (D)
Droop Current Share (A) Overcurrent Latch-off Mode (E)
Gold Plated Signal Connector (G) Overcurrent Foldback Mode (F)
Sealed Pots (C) Standby Power (5VDC @ 1A) (P)**
**Voltage available as long as AC input is present
Model
Certifications
NRTL*** to UL60950-1, CSA C22.2 60950-1-03
BAUART Certification to EN60950-1
CB Test Report in Accordance with IEC60950-1
CE Declaration to Low Voltage Directive 72/73/EEC
*** Nationally Recognized Test Laboratory
Compliance
EN61000-4-5 Level 3 EN61000-4-2 Level 2
EN61000-3-2 EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3 EN61000-4-11
CISPR 11 and 22 FCC Part 15 Class B (conducted)
FM 32227
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com