Description
The 3M™ 9300 Series Particulate Respirators provide e ective
respiratory protection for use in industries where workers will be
exposed to dust particles and/or non-volatile liquid particles.
Tested and CE Approved to EN 149:2001+A1:2009
Foldable, 3-panel design allows for greater facial movement,
comfort and easy storage when not in use.
Individual hygienic packaging protects the respirator from
contamination before use
Nose foam made of sweat absorbent material that is soft on
the skin.
Even strap pressure improves comfort on the neck, face and
head with a secure feel
3M™ Advanced Electret Filter Material gives e ective
ltration with low breathing resistance for consistent high
quality performance
3M™ Cool Flow™ exhalation valve o ers improved
comfort in hot humid environments and/or where work is
hard and physical*.
Coloured headbands for easy identi cation: yellow for FFP1,
blue for FFP2 and red for FFP3
Materials
The following materials are used in the 9300 Series Particulate
Respirators:
Straps Polyisoprene
Staples Steel
Nose Foam Polyurethane
Nose Clip Aluminium
Filter Polypropylene
Valve* Polypropylene
Valve diaphragm* Polyisoprene
These products do not contain components made from natural
rubber latex.
Maximum mass of products:
Unvalved (9310 & 9320) = 10g
Valved (9312, 9322 & 9332) = 15g
Standards
These products meet the requirements of the European Standard
EN149:2001 + A1:2009, fi ltering facepiece respirators for use
against particles. They should be used to protect the wearer from
solid and non-volatile liquid particles only.
Performance tests in this standard include fi lter penetration;
extended exposure (loading) test; fl ammability; breathing resistance
and total inward leakage. A full copy of EN 149:2001+A1:2009
can be purchased from your national standards body.
Designations:
NR = Non reusable (single shift use only)
D = Meets the clogging resistance requirements
Approvals
These products meet the requirements of the European Community
Directive 89/686/EEC (Personal Protective Equipment Directive) and
are thus CE marked.
Certi cation under Article 10, EC Type-Examination and Article 11, EC
quality control, has been issued for these products by BSI Product
Services, Maylands Avenue, Hemel Hempstead, HP2 4SQ, UK
(Noti ed Body number 0086).
Applications
These respirators are suitable for use in concentrations of solid and
non-volatile liquid particles up to the following limits:
Model EN 149+A1
Classifi cation
Exhalation
Valve
Maximum Use
Concentration
9310 FFP1 NR D Unvalved 4 x WEL**
9312 FFP1 NR D Valved 4 x WEL
9320 FFP2 NR D Unvalved 10 x WEL
9322 FFP2 NR D Valved 10 x WEL
9332 FFP3 NR D Valved 20 x WEL
** Workplace Exposure Limit
Respiratory protection is only e ective if it is correctly selected, fi tted and
worn throughout the time when the wearer is exposed to hazards.
Storage and Transportation
The 3M™ 9300 Series Particulate Respirators have a shelf life
of 5 years. End of shelf life is marked on the product packaging.
Before initial use, always check that the product is within the
stated shelf life (use by date). Product should be stored in clean,
dry conditions within the temperature range: – 20°C to
+ 25°C with a maximum relative humidity of <80%. When storing
or transporting this product use original packaging provided.
3M 9300 Series
Particulate Respirators
* 9312, 9322 and 9332 models only
Technical
Datasheet
Please recycle.
© 3M 2010. All rights reserved.
3M United Kingdom plc
3M Centre
Cain Road, Bracknell
Berkshire RG12 8HT
Tel: 0870 60 800 60
www.3M.co.uk/ohes
3M Ireland Limited
The Iveagh Building
The Park
Carrickmines
Dublin 18
Tel: 1 800 320 500
3M Occupational Health & Environmental Safety Group
3M Health & Safety Helpline
0870 60 800 60 (UK) 1 800 320 500 (Ireland)
CH9300DS Iss. 2
Disposal
Contaminated products should be disposed of in accordance
with national regulations.
Fitting Instructions
Before fi tting device, ensure hands are clean.
With reverse side up, separate top and bottom panels to form 1.
a cup shape.
Ensure both panels are fully unfolded. 2.
Cup respirator in one hand with open side towards face. Take 3.
both straps in other hand. Hold respirator under chin, with
nosepiece up, and pull straps over head.
Locate the upper strap across the crown of the head and 4.
the lower strap below the ears. Straps must not be twisted.
Adjust top and bottom panels for a comfortable fi t, ensuring
panels are not folded in.
Using both hands, mould noseclip to the shape of the lower 5.
part of the nose to ensure a close fi t and good seal. Pinching
the noseclip using only one hand may result in less e ective
respirator performance.
The seal of the respirator on the face should be fi t-checked 6.
before entering the contaminated area.
Fit Check
C o v e1. r the front of the respirator with both hands being careful
not to disturb its fi t.
(a) UNVALVED respirator - EXHALE sharply;2.
(b) VALVED respirator - INHALE sharply.
If air leaks around the nose, re-adjust the noseclip to 3.
eliminate leakage. Repeat the above fi t check.
If air leaks at the respirator edges, work the straps back 4.
along the sides of the head to eliminate leakage. Repeat the
above fi t check.
If you CANNOT achieve a proper fi t DO NOT enter the
hazardous area. See your supervisor.
Users should be fi t tested in accordance with national requirements.
For information regarding fi t testing procedures, please contact 3M.
Warnings and Use Limitations
Always be sure that the complete product is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
Proper selection, training, use and appropriate maintenance are essential in order for the product to help protect the wearer from certain airborne contaminants.
Failure to follow all instructions on the use of these respiratory protection products and/or failure to properly wear the complete product during all periods
of exposure may adversely a ect the wearer’s health, lead to severe or life
threatening illness or permanent disability.
For suitability and proper use follow local regulations, refer to all information supplied or contact a safety professional/3M representative.
Before use, the wearer must be trained in use of the complete product in accordance with applicable Health and Safety standards/guidance.
These products do not protect against gases/vapours.
Do not use in atmospheres containing less than 19.5% oxygen. (3M de nition. Individual countries may apply their own limits on oxygen de ciency.
Seek advice if in doubt).
Do not use for respiratory protection against atmospheric contaminants/concen- trations which are unknown or immediately dangerous to life and health (IDLH).
Do not use with beards or other facial hair that may inhibit contact between
the face and the product thus preventing a good seal.
Leave the contaminated area immediately if: a) Breathing becomes di cult.
b) Dizziness or other distress occurs.
Discard and replace the respirator if it becomes damaged, breathing resistance becomes excessive or at the end of the shift.
Never alter, modify or repair this device.
In case of intended use in explosive atmosp heres, contact 3M.