85 SERIES 85 Series - Miniature plug-in timers 7 - 10 A Features 85.02 85.03 85.04 Plug-in timer 85.02 - 2 Pole 10 A 85.03 - 3 Pole 10 A 85.04 - 4 Pole 7 A Multifunctions Seven time scales, from 0.05s to 100h * 94 series sockets * * FOR UL RATINGS SEE: "General technical information" page V * 2 pole, 10 A AC/DC supply non polarized * Plug-in for use with 94 series sockets * 3 pole, 10 A AC/DC supply non polarized * Plug-in for use with 94 series sockets * * * * AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) GI: Pulse delayed 4 pole, 7 A AC/DC supply non polarized * Plug-in for use with 94 series sockets Wiring diagram (without control signal) Wiring diagram (without control signal) Wiring diagram (without control signal) 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) 10/20 10/20 7/15 250/400 250/400 250/250 2,500 2,500 1,750 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load VA 500 500 350 kW 0.37 0.37 0.125 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi 230...240 230...240 230...240 A mW (V/mA) Standard contact material H Supply specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC V AC (50 Hz)/W 12 - 24 - 48 - 110...125 (non polarized) V AC/DC Operating range 2/2 2/2 2/2 AC (0.85...1.1)UN (0.85...1.1)UN (0.85...1.1)UN DC (0.85...1.1)UN (0.85...1.1)UN (0.85...1.1)UN Technical data (0.05...1)s, (0.5...10)s, (5...100)s, (0.5...10)min, (5...100)min, (0.5...10)h, (5...100)h II-2014, www.findernet.com Specified time range Repeatability % 2 2 2 Recovery time ms 20 20 20 Minimum control impulse ms -- -- -- % 5 5 5 cycles 200 * 103 200 * 103 150 * 103 C -20...+60 -20...+60 -20...+60 IP 40 IP 40 IP 40 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category Approvals (according to type) 1 85 SERIES 85 Series - Miniature plug-in timers 7 - 10 A Ordering information Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage, AI, DI, GI, SW functions. 8 5 . 0 4 . 0 . 0 2 4 . 0 0 0 0 Supply voltage 012 = 12 V AC/DC 024 = 24 V AC/DC 048 = 48 V AC/DC 125 = (110...125)V AC/DC 240 = (230...240)V AC Series Type 0 = Multifunction (AI, DI, GI, SW)* * AI = On-delay DI = Interval GI = Pulse delayed SW = Symmetrical flasher (starting pulse on) Supply version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) for 240 V only No. of poles 2 = 2 pole - 10 A 3 = 3 pole - 10 A 4 = 4 pole - 7 A Technical data Insulation 85.02, 85.03 Dielectric strength 85.04 between input and output circuit V AC 2,000 between open contacts V AC 1,000 1,000 between adjacent contacts V AC 2,000 1,550 Insulation (1.2/50 s) between input and output kV 6 2,000 4 EMC specifications Type of test Reference standard Electrostatic discharge EN 61000-4-2 n.a. air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 / 1,000 MHz) EN 61000-4-3 15 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV Surges (1.2/50 s) on common mode EN 61000-4-5 4 kV Supply terminals differential mode EN 61000-4-5 2 kV Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals EN 61000-4-6 10 V Power-frequency (50 Hz) EN 61000-4-8 30 A/m Radiated and conducted emission EN 55022 class B Other data Power lost to the environment without contact current W 1.6 with rated current W 3.7 (85.02) 4.7 (85.03) 3.6 (85.04) Times scales NOTE: time scales and functions must be set before energising the timer. II-2014, www.findernet.com H contact discharge 2 85 SERIES 85 Series - Miniature plug-in timers 7 - 10 A Functions U = Supply voltage LED = Output contact Wiring diagram Contacts Supply voltage NO (SPDT-NO) output contact Open Closed OFF Open x1 - x4 x1 - x2 ON Open x1 - x4 x1 - x2 ON Open (Timing in Progress) x1 - x4 x1 - x2 ON Closed x1 - x2 x1 - x4 Type: 85.02, 85.03, 85.04 (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 85.02 85.03 (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (GI) Pulse delayed. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. H (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). 85.04 U = Supply voltage S = Signal switch Uc = Supply voltage to the timer Signal ON Pulse On mometary closure of Signal Switch (S) > 50 ms, the output contacts transfer and remain so (with self-holding on contact 11-14) for the duration of the preset delay, after which they reset. 11-14 = Self-holding contact II-2014, www.findernet.com = Output contact 3 85 SERIES 94 Series - Sockets and accessories for 85 series timers Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount For timer type Accessories Metal retaining clip (supplied with timer) 6-way jumper link Identification tag Technical data Rated values Dielectric strength Protection category Ambient temperature 94.04 Approvals (according to type): 94.02 Blue 85.02 094.06 C Screw torque Nm Wire strip length mm Max. wire size for 94.02, 94.03 and 94.04 sockets mm2 P A PEAN N T E PEAN T 94.03 Blue 85.03 94.03.0 Black 94.04 Blue 85.04 094.81 094.06.0 094.06 094.06.0 094.06 094.00.4 94.04.0 Black 094.06.0 10 A - 250 V 2 kV AC IP 20 -40...+70 0.5 8 solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 1x10 / 2x14 1x12 / 2x14 6-way jumper link for 94.02, 94.03 and 94.04 sockets 094.06 (blue) Rated values 10 A - 250 V 094.06.0 (black) 094.06 II-2014, www.findernet.com H O O EUR EUR AWG 94.02.0 Black 4 94 Series - Sockets and accessories for 85 series timers Screwless terminal socket 35 mm rail (EN 60715) mount For timer type 85 SERIES 94.54 (blue) 85.02, 85.04 Accessories Metal retaining clip 094.81 6-way jumper link 094.56 Technical data 94.54 Approvals (according to type): Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Wire strip length Max. wire size for 94.54 socket IP 20 C -25...+70 mm 10 solid wire stranded wire mm2 2x(0.2...1.5) 2x(0.2...1.5) AWG 2x(24...14) 2x(24...14) P A PEAN N T E O O T EUR EUR Sockets + jumper link 6-way jumper link 094.56 (blue) Rated values 10 A - 250 V H PEAN II-2014, www.findernet.com 094.56 5 85 SERIES 94 Series - Sockets and accessories for 85 series timers Screw terminal (Plate clamp) socket 94.72 94.72.0 94.73 94.73.0 94.74 94.74.0 panel or 35 mm rail (EN 60715) mount Blue Black Black Black For timer type 85.02 Blue 85.03 Blue 85.02, 85.04 Accessories 94.74 Metal retaining clip (supplied with timer) Approvals (according to type): Screw terminal socket 94.82 panel or 35 mm rail (EN 60715) mount Blue Black For timer type 85.02 85.02 094.81 94.82.0 Accessories Metal retaining clip (supplied with timer) 094.81 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category 94.82 Approvals (according to type): IP 20 Ambient temperature C Screw torque Nm 0.5 mm 8 (94.72, 94.73, 94.74) Wire strip length Max. wire size for 94.72, 94.73, 94.74 mm2 and 94.82 sockets AWG 94.72 94.73 -40...+70 9 (94.82) solid wire stranded wire 1x2.5 / 2x1.5 1x2.5 / 2x1.5 1x14 / 2x16 1x14 / 2x16 94.74 H II-2014, www.findernet.com 94.82 6 85 SERIES 94 Series - Sockets and accessories for 85 series timers Screw terminal (Box clamp) socket 94.82.3 94.82.30 94.84.3 94.84.30 panel or 35 mm rail (EN 60715) mount Blue Black Blue Black For timer type 85.02 85.02, 85.04 Accessories Metal retaining clip 94.84.3 094.81 6-way jumper link Approvals (according to type): 094.06 Identification tag 094.06.0 094.06 094.06.0 094.80.2 Screw terminal (Box clamp) socket 94.84.2 94.84.20 panel or 35 mm rail (EN 60715) mount Blue Black For timer type 85.02, 85.04 Accessories Metal retaining clip 094.81 6-way jumper link 094.06 Identification tag 094.06.0 094.80.2 Technical data 94.84.2 Approvals (according to type): Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Screw torque Wire strip length IP 20 C -40...+70 Nm 0.5 mm 7 Max. wire size for 94.82.3, 94.84.3 and 94.84.2 sockets 2 mm solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 AWG 1x10 / 2x14 1x12 / 2x14 H 94.84.3 P A N T E PEAN II-2014, www.findernet.com O O T EUR EUR 94.84.2 PEAN 6-way jumper link for 94.82.3, 94.84.3 and 94.84.2 sockets 094.06 (blue) Rated values 10 A - 250 V 094.06.0 (black) 094.06 7 85 SERIES 94 Series - Sockets and accessories for 85 series timers Screw terminal (Box clamp) socket 94.92.3 94.92.30 94.94.3 94.94.30 panel or 35 mm rail (EN 60715) mount Blue Black Blue Black For timer type 85.02 85.02, 85.04 Accessories Metal retaining clip 94.94.3 094.81 6-way jumper link Approvals (according to type): 094.06 Identification tag 094.06.0 094.06 094.06.0 094.80.2 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature C -25...+70 Screw torque Nm 0.5 Wire strip length mm 8 P A N T E PEAN T solid wire stranded wire mm2 1x6 / 2x2.5 1x4 / 2x2.5 AWG 1x10 / 2x14 1x12 / 2x14 6-way jumper link for 94.92.3 and 94.94.3 sockets 094.06 (blue) Rated values 10 A - 250 V 094.06.0 (black) 094.06 II-2014, www.findernet.com H PEAN O O EUR EUR Max. wire size for 94.92.3 and 94.94.3 sockets 8