85.02 85.03 85.04
Plug-in timer
85.02 - 2 Pole 10 A
85.03 - 3 Pole 10 A
85.04 - 4 Pole 7 A
Multifunctions
Seven time scales, from 0.05s to 100h
94 series sockets
2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT)
10/20 10/20 7/15
250/400 250/400 250/250
2,500 2,500 1,750
500 500 350
0.37 0.37 0.125
10/0.25/0.12 10/0.25/0.12 7/0.25/0.12
300 (5/5) 300 (5/5) 300 (5/5)
AgNi AgNi AgNi
230…240 230…240 230…240
12 - 24 - 48 - 110…125 (non polarized)
2/2 2/2 2/2
(0.85…1.1)UN(0.85…1.1)UN(0.85…1.1)UN
(0.85…1.1)UN(0.85…1.1)UN(0.85…1.1)UN
(0.05…1)s, (0.5…10)s, (5…100)s, (0.5…10)min, (5…100)min, (0.5…10)h, (5…100)h
± 2 ± 2 ± 2
20 20 20
——
± 5 ± 5 ± 5
200 · 103200 · 103150 · 103
–20…+60 –20…+60 –20…+60
IP 40 IP 40 IP 40
Wiring diagram Wiring diagram Wiring diagram
(without control signal) (without control signal) (without control signal)
AI: On-delay
DI: Interval
SW: Symmetrical flasher
(starting pulse on)
GI: Pulse delayed
1
2 pole, 10 A
AC/DC supply non polarized
Plug-in for use with 94 series
sockets
3 pole, 10 A
AC/DC supply non polarized
Plug-in for use with 94 series
sockets
4 pole, 7 A
AC/DC supply non polarized
Plug-in for use with 94 series
sockets
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) V AC (50/60 Hz)
V AC/DC
Rated power AC/DC V AC (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
AI: On-delay
DI: Interval
SW: Symmetrical flasher
(starting pulse on)
GI: Pulse delayed
AI: On-delay
DI: Interval
SW: Symmetrical flasher
(starting pulse on)
GI: Pulse delayed
Features
FOR UL RATINGS SEE:
“General technical information” page V
II-2014, www.findernet.com
85 Series - Miniature plug-in timers 7 - 10 A 85
SERIES
H
2
Times scales
Insulation
Dielectric strength 85.02, 85.03 85.04
between input and output circuit V AC 2,000 2,000
between open contacts V AC 1,000 1,000
between adjacent contacts V AC 2,000 1,550
Insulation (1.2/50 µs) between input and output kV 6 4
EMC specifications
Type of test Reference standard
Electrostatic discharge contact discharge EN 61000-4-2 n.a.
air discharge EN 61000-4-2 8 kV
Radio-frequency electromagnetic field (80 ÷ 1,000 MHz) EN 61000-4-3 15 V/m
Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV
Surges (1.2/50 µs) on common mode EN 61000-4-5 4 kV
Supply terminals differential mode EN 61000-4-5 2 kV
Radio-frequency common mode (0.15 ÷ 80 MHz) on Supply terminals EN 61000-4-6 10 V
Power-frequency (50 Hz) EN 61000-4-8 30 A/m
Radiated and conducted emission EN 55022 class B
Other data
Power lost to the environment without contact current W 1.6
with rated current W 3.7 (85.02) 4.7 (85.03) 3.6 (85.04)
Technical data
Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage, AI, DI, GI, SW functions.
Ordering information
Supply voltage
012 = 12 V AC/DC
024 = 24 V AC/DC
048 = 48 V AC/DC
125 = (110…125)V AC/DC
240 = (230…240)V AC
Supply version
0 = AC (50/60 Hz)/DC
8 = AC (50/60 Hz) for 240 V only
Series
Type
0 = Multifunction (AI, DI, GI, SW)*
* AI = On-delay
DI = Interval
GI = Pulse delayed
SW = Symmetrical flasher (starting pulse on)
No. of poles
2 = 2 pole - 10 A
3 = 3 pole - 10 A
4 = 4 pole - 7 A
0 4 0 00 0 0
... .
02485
NOTE: time scales and functions must be set before energising the timer.
II-2014, www.findernet.com
85
SERIE S85 Series - Miniature plug-in timers 7 - 10 A
H
3
Functions
Contacts
NO (SPDT-NO)
output contact
Supply
voltage
LED
OFF
ON
ON
ON
= Supply
voltage
= Output
contact Open
Open
Open
(Timing in Progress)
Closed
x1 - x4
x1 - x4
x1 - x4
x1 - x2
x1 - x2
x1 - x2
x1 - x2
x1 - x4
Open Closed
(AI) On-delay.
Apply power to timer.
Output contacts transfer after preset time has elapsed.
Reset occurs when power is removed.
(DI) Interval.
Apply power to timer.
Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
Wiring diagram Type: 85.02, 85.03, 85.04
85.02
85.03
85.04
(GI) Pulse delayed.
Apply power to timer. Output contacts transfer after
preset time has elapsed. Reset occurs after a fixed
time of 0.5s.
(SW) Symmetrical flasher (starting pulse on).
Apply power to timer.
Output contacts transfer immediately and cycle
between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
Signal ON Pulse
On mometary closure of Signal Switch (S) > 50 ms,
the output contacts transfer and remain so (with
self-holding on contact 11-14) for the duration of the
preset delay, after which they reset.
U= Supply voltage
S= Signal switch
Uc= Supply voltage
to the timer
11-14 = Self-holding
contact
= Output contact
U
II-2014, www.findernet.com
85 Series - Miniature plug-in timers 7 - 10 A 85
SERIES
H
094.06
4
Approvals
(according to type):
Screw terminal (Box clamp) socket 94.02 94.02.0 94.03 94.03.0 94.04 94.04.0
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black Blue Black
For timer type 85.02 85.03 85.04
Accessories
Metal retaining clip (supplied with timer) 094.81
6-way jumper link
094.06 094.06.0 094.06 094.06.0 094.06 094.06.0
Identification tag 094.00.4
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 8
Max. wire size for 94.02, 94.03 and 94.04 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
6-way jumper link for 94.02, 94.03 and 94.04 sockets 094.06 (blue) 094.06.0 (black)
Rated values 10 A - 250 V
94.04
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
II-2014, www.findernet.com
85
SERIE S94 Series - Sockets and accessories for 85 series timers
H
5
94.54
Screwless terminal socket 35 mm rail (EN 60715) mount 94.54 (blue)
For timer type 85.02, 85.04
Accessories
Metal retaining clip 094.81
6-way jumper link 094.56
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –25…+70
Wire strip length mm 10
Max. wire size for 94.54 socket solid wire stranded wire
mm22x(0.2…1.5) 2x(0.2…1.5)
AWG 2x(24…14) 2x(24…14)
Approvals
(according to type):
094.56
6-way jumper link 094.56 (blue)
Rated values 10 A - 250 V
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
Sockets +
jumper link
II-2014, www.findernet.com
94 Series - Sockets and accessories for 85 series timers 85
SERIES
H
6
94.82
94.74
Screw terminal (Plate clamp) socket 94.72 94.72.0 94.73 94.73.0 94.74 94.74.0
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black Blue Black
For timer type 85.02 85.03 85.02, 85.04
Accessories
Metal retaining clip (supplied with timer) 094.81
Screw terminal socket 94.82 94.82.0
panel or 35 mm rail (EN 60715) mount Blue Black
For timer type 85.02 85.02
Accessories
Metal retaining clip (supplied with timer) 094.81
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 8 (94.72, 94.73, 94.74) 9 (94.82)
Max. wire size for 94.72, 94.73, 94.74 solid wire stranded wire
and 94.82 sockets mm21x2.5 / 2x1.5 1x2.5 / 2x1.5
AWG 1x14 / 2x16 1x14 / 2x16
Approvals
(according to type):
Approvals
(according to type):
94.82
94.72 94.73 94.74
II-2014, www.findernet.com
85
SERIE S94 Series - Sockets and accessories for 85 series timers
H
94.84.3
94.84.2
094.06
94.84.2
94.84.3
Approvals
(according to type):
Screw terminal (Box clamp) socket
94.82.3 94.82.30 94.84.3 94.84.30
panel or 35 mm rail (EN 60715) mount
Blue Black Blue Black
For timer type 85.02 85.02, 85.04
Accessories
Metal retaining clip 094.81
6-way jumper link 094.06 094.06.0 094.06 094.06.0
Identification tag 094.80.2
Screw terminal (Box clamp) socket
94.84.2 94.84.20
panel or 35 mm rail (EN 60715) mount
Blue Black
For timer type 85.02, 85.04
Accessories
Metal retaining clip 094.81
6-way jumper link 094.06 094.06.0
Identification tag 094.80.2
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 7
Max. wire size for 94.82.3, 94.84.3 solid wire stranded wire
and 94.84.2 sockets mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
Approvals
(according to type):
7
6-way jumper link for 94.82.3, 94.84.3 and 94.84.2 sockets 094.06 (blue) 094.06.0 (black)
Rated values 10 A - 250 V
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
II-2014, www.findernet.com
94 Series - Sockets and accessories for 85 series timers 85
SERIES
H
094.06
94.94.3
Approvals
(according to type):
Screw terminal (Box clamp) socket 94.92.3 94.92.30 94.94.3 94.94.30
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black
For timer type 85.02 85.02, 85.04
Accessories
Metal retaining clip 094.81
6-way jumper link 094.06 094.06.0 094.06 094.06.0
Identification tag 094.80.2
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –25…+70
Screw torque Nm 0.5
Wire strip length mm 8
Max. wire size for 94.92.3 and 94.94.3 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
6-way jumper link for 94.92.3 and 94.94.3 sockets 094.06 (blue) 094.06.0 (black)
Rated values 10 A - 250 V
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
8
II-2014, www.findernet.com
85
SERIE S94 Series - Sockets and accessories for 85 series timers
H