Fluke 355/353 True-rms 2000 A Clamp Meters Technical Data High current and a large jaw, make these clamps well suited for industrial and utility applications Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in highcurrent applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements. * * * * * * * * * * * N10140 Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this the most versatile tool for utilities, electrical contractors, and industrial service technicians. Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures `power-on' surge current with accuracy and repeatability High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows users to perform multiple tests with only one tool (355 only) Resistance to 400 kW coupled with a continuity beeper, provide the convenience of a multimeter (355 only) Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A large backlit display allows for easy visibility in low-lit areas Use the display hold feature to capture readings even when the display cannot be viewed Use the low-pass filter to smooth out noisy loads and stabilize readings Specifications Electrical specifications Current measurement dc and ac 10 Hz to 100 Hz Range Resolution Accuracy, A Trigger Level for Inrush Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 40 A 10 mA 1.5 % rdg + 15 digits 0.50 A 2.50 A 0.50 A 400 A 100 mA 1.5 % rdg + 5 digits 5.0 A 2.5 A 2.5 A 1A 1.5 % rdg + 5 digits 5A 8A 8A 2000 A; 1400 ac rms Crest Factor (50/60 Hz) Range Crest Factor* 40 A 2 @ 33 A, 2.4 @ 27 A 400 A 2 @ 330 A, 2.4 @ 270 A 2000 A; 1400 ac rms 2 @ 1000 A, 2.4 @ 833 A *Add 2 % to error spec for CF > 2 Current measurement ac 100.1 Hz to 1 kHz Range Resolution Accuracy > 10 A Trigger Level for Inrush Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 40 A 10 mA 3.5 % rdg + 15 digits 0.50 A 2.50 A 0.50 A 400 A 100 mA 3.5 % rdg + 5 digits 5.0 A 2.5 A 2.5 A 1A 3.5 % rdg + 5 digits 5A 8A 8A 2000 A; 1400 ac rms Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively. Range Resolution Accuracy Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 4V 1 mV 1 % rdg + 10 digits 0.050 V 0.050 V 40 V 10 mV 1 % rdg + 5 digits 0.25 V 0.25 V 400 V 100 mV 1 % rdg + 5 digits 6V 6V 600 V ac rms 1V 1 % rdg + 5 digits 6V 6V 1000 V dc 1V 1 % rdg + 5 digits N/A N/A Voltage measurement (355 only) ac 100.1 Hz to 1 kHz 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively. Range Resolution Accuracy Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 4V 1 mV 3 % rdg + 10 digits 0.050 V 0.050 V 40 V 10 mV 3 % rdg + 5 digits 0.25 V 0.25 V 400 V 100 mV 3 % rdg + 5 digits 6V 6V 1V 3 % rdg + 5 digits 6V 6V 600 V ac rms Ohms measurement (355 only) Range Resolution Accuracy 400 0.1 1.5 % + 5 digits 4 k 1 1.5 % + 5 digits 40 k 10 1.5 % + 5 digits 400 k 100 1.5 % + 5 digits 2 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters Continuity beeper (355 only) On at 30 Off at 100 Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) Accuracy - 5.0 Hz to 100 Hz 0.2 % + 2 counts Accuracy - 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger level Refer to current and voltage tables General specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6 Battery life (with typical usage, backlight off) 100 hours Test leads Rated to 1000 V Weight .814 kg (1.8 lb) Jaw size 58 mm (2.28 in) Dimensions (LxWxD) 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III Environmental specifications Operating temperature 32 F to + 122 F (0 C to +50 C) Storage temperature -4 F to 140 F (-20 C to +60 C) Operating humidity 0 to 95 % (non-condensing) Operating altitude 2000 m Storage altitude 10,000 m IP rating 42 (indoor use only) Drop test requirements 1m EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 Temperature coefficients Current: 0.1 % of reading per C outside 22 C to 24 C Voltage: 0.1 % of reading per C outside 22 C to 24 C Ordering information: Fluke-353 AC/DC True-rms Clamp Meter, 2000 A, Amps only Includes: C43 Soft Carrying Case, 6 AA batteries, and users manual Fluke-355 AC/DC True-rms Clamp Meter, 2000 A Includes: C43 Soft Carrying Case, 6 AA batteries, TL224 1.5 m Silicone Rubber Test Leads, TP2 Test Probes, AC285 Alligator Clips, and users manual Fluke. Keeping your world up and running.(R) Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com Fluke-355 3 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters Fluke-353 (c)2007 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 9/2007 3094045 D-EN-N Rev A