The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
27/12/2011
1
Product data sheet
Characteristics
XACS102
spring return contact block - 1 NC - base
mounting
Main
Range of product Harmony XAC
Product or component
type
Contact block
Component name XACS
Electrical circuit type Control circuit
Contact block type Single
Type of operator Spring return
Product compatibility XACA
Contacts type and
composition
1 NC
Mounting of block Base mounting
Contacts operation Slow-break
Complementary
Connections - terminals Screw clamp terminals, connection capacity: 1 x 0.5...1 x 2.5 mm² without cable
end
Screw clamp terminals, connection capacity: 1 x 0.5...2 x 1.5 mm² with cable end
Mechanical durability 1000000 cycles
Contact code designation A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 10 A
[Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Resistance across terminals <= 25 mOhm
Operating force 8 N
Short circuit protection 10 A fuse protection by cartridge fuse type gG
Rated operational power in W 40 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Terminals description ISO n°1 (11-12)NC
Product weight 0.03 kg
Environment
Standards CSA C22-2 No 14
EN/IEC 60947-5-1
UL 508
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Vibration resistance 15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Shock resistance 100 gn conforming to IEC 60068-2-27
Class of protection against electric shock Class II conforming to IEC 61140
RoHS EUR status Compliant
RoHS EUR conformity date 1014