COUNT/RATE COUNT/RATE
87 610 150 SERIES
ELAPSED TIME INDICATOR
• Voltage Input Version
• 6 Digit .3˝ High LCD Display
• 4 Selectable Time Ranges:
- Hours, 1/10 Hours
- Minutes, 1/10 Minutes
- Seconds, 1/10 Seconds
- Hours, Minutes, Seconds
• NEMA 4 Front Panel
GENERAL FEATURES:
The 87 610 150 Series is an elapsed time indicator in a DIN-sized
(24 x 48mm) enclosure. The start/stop input can be a 5 to 50 VAC/DC
and 48 to 240 VAC voltage pulse. The unit is powered by an internal
lithium battery which can be disconnected via a dip-switch for storage
purposes.
SPECIFICATIONS:
Display . . . . . . . . . . . . . . . . . . . . . . 6 Digit LCD
Display Height . . . . . . . . . . . . . . . . 0.3˝
Accuracy . . . . . . . . . . . . . . . . . . . . . +50 PPM
Input
Start/Stop and Reset Inputs . . . . 5 to 50 VAC/DC
48 to 240 VAC
Min. Closure Time . . . . . . . . . . . . 40 ms
Power Supply . . . . . . . . . . . . . . . . . Internal lithium battery (5 year life)
Connection . . . . . . . . . . . . . . . . . . . Screw Terminal
Front Panel Rating . . . . . . . . . . . . . NEMA 4 (IP66)
Operating Temperature . . . . . . . . . . +14 to 122°F (-10 to 50°C)
Storage Temperature . . . . . . . . . . . -13 to 158°F (-25 to 70°C)
Weight . . . . . . . . . . . . . . . . . . . . . . 2.1 oz. (60g)
DIMENSIONS: (mm)
ORDERING INFORMATION:
Voltage Input Version 87 610 150
WIRING:
87 610 150
1- 48 to 240 VAC Reset Input
2- OV Reset Input
3- 5 to 50 VAC/DC Reset Input
4- 5 to 50 VAC/DC Start/Stop Input
5- OV Start/Stop Input
6- 48 to 240 VAC Start/Stop Input
123456
~~/– ~/– ~
AB
Reset
Input
Start/Stop
Input
48.
240V
5.
50V
5.
50V
48.
240V
48
24
3
64
44.6
21.8
44.8
+0.6
- 0
+0.3
- 0
22
Products and specifications subject to change without notice.
Consult factory for application assistance.
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
7-8
UL
®
CUS LISTED