Rev.07.08.16_#1.0
DA10 Series
Page 1
Technical Reference Note
DA10-050 Series
10 Watts
External Power Adapters
Total Power: 10 Watts
Input Voltage: 90-264 Vac
# of Outputs: Single
Special Features
Small Size 44 x 39.5 x 25 mm
excluding AC pins
High Average Loading Efficiency
79%
2-pin Input Class II
USB connector output
Product Descriptions
The new standard 10W charger platform provides small-size, high efficiency &
low cost features. It meets new European
CoC
v5 Tier 2 & US
DoE
Level VI
USB connector output
-10 ºC to +40 ºC Operating
Temperature Range
Reinforced Insulation
3000 Vac rms
Over-voltage Protection
Over-temperature Protection
Over-current Protection
Short circuit Protection
Elegant Enclosure ID Design
European CoC v5 Tier 2 & US DoE
VI Compliant
One Year Warranty
RoHS 6/6 , WEEE and REACH
Compliant
Safety
cUL/UL 60950-1
IEC/EN 60950-1
IEC 62368-1
CCC
CE
GS
Design to meet:
NOM-NYCE, SPRING, IRAM, C-
Tick, NSW
low cost features. It meets new European
CoC
v5 Tier 2 & US
DoE
Level VI
energy saving requirements.
The integrated primary side regulation chip topology provides simplified & low-
cost design. It can meet extremely low standby power (< 75mW) and high
average loading efficiency (>79%). The enclosure temperature rise is < 45 oC in
full temperature range from -10 to 40 oC operating.
Extra features include over-voltage, over-current, short-circuit and over-
temperature protections.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 2
Technical Reference Note
Model Numbers
Options
Standard Input Voltage Range Output Voltage Minimum Load Maximum Load
DA10-050US 90-264 Vac 5Vdc 0A 2A
DA10-050CH 90-264 Vac 5Vdc 0A 2A
DA10-050EU 90-264 Vac 5Vdc 0A 2A
DA10-050UK 90-264 Vac 5Vdc 0A 2A
AC Plug Configuration for Fixed Plug
U.S. 2-prong US
China 2-prong CH
Europe 2-prong EU
UK 3-prong UK
Artesyn Embedded Technologies
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 3
Technical Reference Note
Table 1. Absolute Maximum Ratings:
Parameter Model Symbol Min Typ Max Unit
Input Voltage
AC continuous operation All models VIN,AC 90 - 264 Vac
Maximum Output Power All models PO,max - - 10 W
Isolation Voltage
Input to output All models - - 3000 Vac
Ambient Operating Temperature All models TA-10 - +40 oC
Storage Temperature All models TSTG -40 - +85 oC
Electrical Specifications
Absolute Maximum Ratings
Stress in excess of those listed in the “Absolute Maximum Ratings” may cause permanent damage to the power supply.
These are stress ratings only and functional operation of the unit is not implied at these or any other conditions above
those given in the operational sections of this TRN. Exposure to any absolute maximum rated condition for extended
periods may adversely affect the power supply’s reliability.
Artesyn Embedded Technologies
Humidity(non-condensing) All models 5 - 95 %
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 4
Technical Reference Note
Input Specifications
All parameters defined at 25 oC ambient temperature, unless other specified.
Table 2. Input Specifications:
Parameter Conditions Symbol Min Typ Max Unit
Operating Input Voltage, AC All VIN,AC 90 - 264 Vac
Input AC Frequency All fIN 47 50/60 63 Hz
Input Surge Voltage
100ms.
VIN,AC = 264Vac to
300Vac and back to
264Vac Max
VIN,surge - - 300 Vac
Maximum Input Current
(IO= IO,max)VIN,AC = 115Vac IIN,max - - 300 mA
No Load Input Power
(VO= On, IO= 0A)
VIN,AC = 115Vac /
230Vac PIN,standby - - 75 mW
Efficiency
VIN,AC = 230Vac
IO= 10% IO,max
IO= 25% - 100% IO,max
η70
79
-
-
-
-
%
%
Leakage Current to earth ground
IN,AC
= 264Vac
I
Leakage
-
-
100
uA
Artesyn Embedded Technologies
Leakage Current to earth ground
IN,AC
= 264Vac
I
Leakage
-
-
100
uA
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 5
Technical Reference Note
Table 3. Output Specifications:
Parameter Condition Symbol Min Typ Max Unit
Output Voltage Regulation All VO4.75 5.00 5.25 Vdc
Output Current All IO- - 2 A
Output Ripple, pk-pk
Measure with a 0.1uF
ceramic capacitor in
parallel with a 10uF
tantalum capacitor, 0
to 20MHz bandwidth
VO0 - 100 mVPK-PK
VODynamic Response 50% load change,
slew rate = 0.5A/uS VO4.1 - 6.0 Vdc
Output Rise Time All TRISE - - 100 mSec
Hold-up Time VIN,AC = 115Vac
IO = IO,max
THold-up - 10 - mSec
Output Specifications
Artesyn Embedded Technologies
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 6
Technical Reference Note
DA10-050CH Performance Curves
Figure 1: DA10-050CH Turn-on Delay via AC mains
Vin = 115Vac, Full Load: IO = 2A
Ch 1: AC Mains Ch 2: VO
Figure 2: DA10-050CH Turn-on Delay via AC mains
Vin = 230Vac, Full Load: IO = 2A
Ch 1: AC Mains Ch 2: VO
Artesyn Embedded Technologies
Figure 5: DA10-050CH Start up Inrush Current
Vin = 264Vac, Io = 0A, Turn On Phase = 90°
°°
°
Ch 1: VIN Ch 3: IIN
Figure 4: DA10-050CH Hold-up Time
Vin = 264Vac / 47Hz / 0°
°°
°, Full Load: IO= 2A
Ch 1: AC Mains Ch 2: VO
Figure 6: DA10-050CH Output Voltage Startup
Vin = 90Vac, Full Load: IO= 2A
Ch 1: VO
Figure 3: DA10-050CH Hold-up Time
Vin = 90Vac / 63Hz / 0°
°°
°, Full Load: IO= 2A
Ch 1: AC Mains Ch 2: VO
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 7
Technical Reference Note
DA10-050CH Performance Curves
Figure 7: DA10-050CH Transient Response Vo Deviation (low to high)
50% to 100% load change, 1A/uS slew rate, VIN = 115Vac
Ch 2: VOCh 3: IO
Figure 8: DA10-050CH Transient Response Vo Deviation (high to low)
100% to 50% load change, 1A/uS slew rate, VIN = 115Vac
Ch 2: VOCh 3: IO
81
82
Efficiency (%)
Artesyn Embedded Technologies
Figure 9: DA10-050CH Efficiency Curves @ 25 oC
115 Vac 230 Vac
Loading: IO= 25% increment to 2A
78
79
80
0.5 1 1.5 2
Output Current (A)
Efficiency (%)
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 8
Technical Reference Note
Protection Function Specification
Over Voltage Protection (OVP)
Over Voltage Protection is triggered when the PSU has an internal fault which results in the output rising over the
regulation limit. The power supply will bounce during overvoltage and recover to normal after remove the fault condition.
Over Current Protection (OCP)
Current Limitation at >100% output current, Hiccup mode. The DA10 series includes internal current limit circuitry to
prevent damage in the event of overload or short circuit. Recovery is automatic when the overload is removed.
Parameter Min Nom Max Unit
VOOutput Overvoltage / / 6.5 Vdc
Parameter Min Nom Max Unit
V
O
Output Overcurrent 2 / / A
Artesyn Embedded Technologies
Short Circuit Protection (SCP)
The DA10 series will withstand a continuous short circuit with no permanent damage, applied to its output during start-up
or while running. The output will recover to normal after the short-circuit is removed.
Over Temperature Protection (OTP)
The power supply is internally protected against over temperature conditions. When the OT circuit is activated, the power
supply will latch off, requiring AC power recycling to restart the power supply with 5 seconds “off time” at least.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 9
Technical Reference Note
Mechanical Specifications
Mechanical Outline – DA10-050US
Artesyn Embedded Technologies
Note: All dimensions in mm.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 10
Technical Reference Note
Mechanical Outline – DA10-050CH
Artesyn Embedded Technologies
Note: All dimensions in mm.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 11
Technical Reference Note
Mechanical Outline – DA10-050EU
Artesyn Embedded Technologies
Note: All dimensions in mm.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 12
Technical Reference Note
Mechanical Outline – DA10-050UK
Artesyn Embedded Technologies
Note: All dimensions in mm.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 13
Technical Reference Note
Environmental Specifications
EMC Requirements
DA10 series power supply is designed to meet the following EMC immunity specifications:
Table 4. EMC Immunity Specifications:
Document Description
FCC Part 15 Subpart B/ EN55022, Class B Conducted and Radiated EMI Limits
EN61000-3-3 Voltage Fluctuations, δmax 4%
EN61000-4-2
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques Electrostatic discharge immunity test. +/-8KV contact
discharge, performance Criteria B
EN61000-4-3
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Radiated, radio-frequency, electromagnetic field immunity test,
Criteria A
EN61000-4-4
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Electrical Fast Transient/Burst Immunity Test. +/-1KV , I/O and
Artesyn Embedded Technologies
signal ports performance Criteria A.
EN61000-4-5 Electromagnetic Compatibility (EMC) - Testing and measurement
techniques. +/-1KV for DC ports performance criteria A.
EN61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields –
performance criteria A
EN61000-4-11
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques : Voltage Dips and Interruptions: performance Criteria B(For
100% reduction, Criteria C).
High Frequency Pulses / Rings longer than
250ns Common Mode Noise: Less than or equal to 2.0 Vpp.
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 14
Technical Reference Note
Safety Certifications
The DA10-050 series power supply is in compliance with the following safety requirements.
Table 5. Safety Certifications
Document File # Description
cUL/UL 60950-1 E132002-A402-UL US and Canada Requirements
Level VI Compliance 15459 US Efficiency Standards for External Power Supplies.
IEC/EN 60950-1 E132002-A402-CB-1 European Requirements
IEC 62368-1 DK-46911-UL Audio/video, information and communication technology equipment.
CB Certificate and Report DK-49542-UL (All CENELEC Countries)
CHINA CCC Approval 2015010907769437 China Requirements
CE Mark 8544 LVD
NOM-NYCE Mexico Approval
GS GS Mark Certification
SPRING PSB Spring certification
IRAM Argentina IRAM certification
Artesyn Embedded Technologies
C-Tick C-Tick mark
NSW NSW Certificate
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 15
Technical Reference Note
Environmental Specification
.
Table 6. Environmental Specifications:
Parameter Condition Min Typ Max Unit
Operating Ambient Temperature Natural Convection
IO = IO,max
0 - 40 oC
Case (Enclosure) Temperature Rise over
Ambient Temperature.
Natural Convection
TA= 40oC- - 45 oC
Electrolytic Cap. Life Expectancy VIN,AC = 115 / 230Vac
IO = IO,max
1.5 - - 10 KHr
MTBF VIN,AC = 115 / 230Vac
IO = IO,max
1 - - 100 KHr
Acoustic Noise All - - 25 dBA
Artesyn Embedded Technologies
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 16
Technical Reference Note
Weight
The PSU weight is 34 gram maximum.
Artesyn Embedded Technologies
Technical Reference Note
Rev.07.08.16_#1.0
DA10 Series
Page 17
Technical Reference Note
Record of Revision and Changes
Issue Date Description Originators
1.0 07.08.2016 First Issue S. Yang
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com