2Specifications are subject to change without notice (28.09.99)
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
Mode of Operation
The G 219600.. Dupline
®
mas-
ter module (DMM) is part of the
Dupline
®
concept for multi-
plexing the push-button and
lamp signals in elevators. As
shown on the wiring diagram a
3-wire bus with signal, DC-
power and common GND
goes throughout the shaft to all
the push-button panels and
floor indicators, and to the car.
The DMM is connected to a
standard DC-supply which it
synchronizes with the Dupline
®
carrier signal before it is output
to supply the push-button
panels. The synchronization is
necessary in order to enable
the Dupline
®
and DC-supply to
share the GND-wire.
The most cost-effective way to
interface the elevator controller
to the master module is to
make use of the RS 485 port
(see wiring diagram). In this
way, the size and the number
of controller I/O-board(s) can
be reduced significantly, since
the I/O-terminals for lamps,
pushbuttons and floor-indica-
tors are no longer needed.
Based on requests from cus-
tomers, special versions of the
master module for automatic
communication with specific
PLC’s/Controllers are devel-
oped continuously. This makes
the interfacing very easy, since
these devices automatically
transfer the Dupline
®
data to/
from the internal memory of
the PLC/ Controller. The ver-
sions available for the moment
are listed under “Type Selec-
tion”. More detailed information
about interfacing to the indi-
vidual PLC-types are available.
The standard version G 2196
0000 700 utilizes a general pur-
pose protocol for implementa-
tion in any PLC/Controller soft-
ware. In this case, the commu-
nication is not automatic, since
it must be driven from the
application software.
Another way to implement the
elevator controller interface is
to make hardwired connec-
tions between the I/O’s of the
controller and Dupline
®
-mo-
dules positioned next to it, thus
making use of the peer-to-peer
communication capability of
Dupline
®
. This solution is less
cost-effective, but highly flexi-
ble since existing and different
control-systems can be used.
G 2196 00..
Wiring Diagram
Car
panel
GND
Signal
Power
G 2196 00..
1 2 3 4 5
DIP-switch Setting for G21960000700
ON
232º
12345
The device no. and number
of Dupline®channels are
selected by means of 5
DIP-switches.
SW ON OFF
1-4 Device no.
5 64 ch. 128 ch.
Accessories
Data brochure DAT DMM
(RS 485 protocol specification and design hints)
+-
=
~
Terminal Function
1 GND
2 Dupline®Signal
3 Power Out
4 GND
5 DC Power Supply
Lift
Controller RS 485
General Specifications
Power ON delay 2 s
Indication for
RS 485 Tx LED, red
Supply ON LED, green
Dupline®carrier LED, yellow
Environment
Pollution degree 2 (IEC 60664)
Operating temperature 0° to +50°C (+32° to +122°F)
Storage temperature
-50° to +85°C (-58° to +185°F)
Humidity (non-condensing) 20 to 80%
Mechanical resistance
Shock 15 G (11 ms)
Vibration 2 G (6 to 55 Hz)
Dimensions 86 x 54 mm open printed
circuit board, 4.2 mm hole in
each corner for mounting
Weight 100 g
1. floor
2. floor
3. floor
n floor