Preliminary Technical Data GENERAL DESCRIPTION The ADISEVAL is a PC-based evaluation system for many of the iSensorTM products. It comes with a Parallel Interface Board, parallel interface cable, 2 12-pin ribbon cables, and the iSensorTM CD, which contains product documentation and evaluation software. GETTING STARTED Getting started with this system requires four simple steps. iSensorTM PC Evaluation System ADISEVAL The software contains help files that describe each function of the software. The right button on the mouse has the ability to speed up changes when the Pointer is placed over titles, graph axes and waveform data. See Figure 4 (ADIS16003, ADIS16006), Figure 5 (ADIS16080, ADIS16100), Figure 6 (ADIS16201), Figure 7 (ADIS16203), Figure 8 (ADIS16209) and Figure 9 (ADIS16250) for basic software assistance. Table 1. Power Supply Hook-up - J2 1. Connect J2 of the Parallel Interface Board (see Figure 1) to the appropriate power supply, using Table 1. For simplicity, connect pin 1 to pin 4 and connect pin 2 to pin 3. Set the voltage on the power supply per Table 2. Turn power off. 2. Install the ADIS16XXX/PCBZ evaluation board on the Parallel Interface Board, using 2mm machine screws and the two 12-pin ribbon cables, as shown in Figure 2. Make sure that these cables are aligned correctly on each header before applying power. Hook up the system to a PC using the parallel cable. 3. Locate the product-specific evaluation software on the iSensorTM CD or download it from: www.analog.com/isensor-evaluation. See Table 3 for a list of products supported by each installation package. 4. Unpack the zip file and double click on the setup.exe file. Follow the prompts to install the software. 5. Go to the created directory. In most cases, this will be a subdirectoy under "C:\ProgramFiles\Analog Devices iSensors\." Double-click on the giveio.exe. Follow the prompts to install this driver, which enables the parallel port communications in the PC. 6. Double click on the ADIS*.exe file to start the software. 7. Click on "Interface" and select, "Parallel." Enter the address of the parallel port on the PC and click the "OK" button. The parallel port address can be found under the Device Manager in Windows XP. Pin Number 1 2 3 4 Function Digital I/O Power Supply Common Common Sensor Power Supply NOTE: No reverse polarity protection provided. Table 2. Power Supply Voltages Evaluation Board ADIS16003/PCBZ ADIS16006/PCBZ ADIS16060/PCBZ ADIS16080/PCBZ ADIS16100/PCB ADIS1620x/PCBZ ADIS1625x/PCBZ Power Supply Voltage +3.0 to +5.25V +3.0 to +5.25V +4.75 to +5.25V +4.75 to +5.25V +4.75 to +5.25V +3.0 to +3.6V +4.75 to +5.25V Table 3. Evaluation Software Installation Package Filename 003ES(x).zip 201ES(x).zip 203ES(x).zip 204ES(x).zip 209ES(x).zip 250ES(x).zip Supported Products ADIS16003 ADIS16006 ADIS16060 ADIS16080 ADIS16100 ADIS16201 ADIS16203 ADIS16024 ADIS16209 ADIS16250 ADIS16251 ADIS16255 ORDERING GUIDE Model ADISEVAL Package Description iSensorTM PC Evaluation System Rev. Pr.C Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. www.analog.com Tel: 781.329.4700 Fax: 781.326.8703 (c) 2008 Analog Devices, Inc. All rights reserved. ADISEVAL Pin 1 Figure 1 - iSensorTM PC Interface Board Layout Rev. PrC | Page 2 of 10 Preliminary Technical Data ADISEVAL 12-pin ribbon cables are installed here Figure 2 - iSensorTM PC Interface Board with ADIS16201/PCBZ installed Rev. PrC | Page 3 of 11 ADISEVAL VCC VDD J2 1725672 DNI DNI DNI DNI DNI DNI E10 E9 J1 E12 E11 E1 E2 E3 E4 E5 E6 E7 E8 E13 Figure 3 - iSensorTMPC Evaluation Board Schematic Rev. PrC | Page 4 of 10 Preliminary Technical Data ADISEVAL 3 4 2 1 5 FIGURE FLAG NOTES: 1. Set the Device type to ADIS16003 or ADIS16006. 2. Set the axis to measure. Test function exercises a self-test during a single sweep on the screen. 3. Plot and log data to files. 4. Set up data logging parameters. 5. Right click over Y-Axis to adjust scale and offset of the plot. Figure 4. ADIS16003 and ADIS16006 Evaluation Software Rev. PrC | Page 5 of 11 ADISEVAL 3 4 2 1 5 FIGURE FLAG NOTES: 1. Set the Device type to ADIS16060, ADIS16080 or ADIS16100. 2. Set the output channel to measure. Test function exercises a self-test during a single sweep on the screen. 3. Plot and log data to files. 4. Set up data logging parameters. 5. Right click over Y-Axis to adjust scale and offset of the plot. Figure 5. ADIS16060, ADIS16080 and ADIS16100 Evaluation Software Screen Rev. PrC | Page 6 of 10 Preliminary Technical Data ADISEVAL 1 4 2 3 FIGURE FLAG NOTES: 1. Perform a single read of the ADIS16201's output data 2. Start and stop continuous reading of the ADIS16201's output data. The acquisition loop delay time provides rough control over sample times. Please note that this data will not have a high degree of coherence. 3. Select the file data logging option. 4. Configure the ADIS16201's internal sample rate and filter response. Figure 6. ADIS16201 Evaluation Software Rev. PrC | Page 7 of 11 ADISEVAL 1 5 4 2 6 3 FIGURE FLAG NOTES: 1. Perform a single read of the ADIS16203's output data 2. Start and stop continuous reading of the ADIS16203's output data. The acquisition loop delay time provides rough control over sample times. Please note that this data will not have a high degree of coherence. 3. Select the file data logging option. 4. Configure the ADIS16203's internal sample rate and filter response. 5. Graphical orientation. Note that for incline angle - 0, the corner dot would be in the lower, left hand corner. 6. Alarm monitoring. Note that these turn red on alarm condition. They maintain their status until the Reset button is pressed, even if the error condition has cleared. Figure 7. ADIS16203 Evaluation Software Rev. PrC | Page 8 of 10 Preliminary Technical Data 1 ADISEVAL 3 6 2 4 5 FIGURE FLAG NOTES: 1. Perform a single read of the ADIS16209's output data 2. XINCL_OUT and YINCL_OUT are horizontal incline outputs. ROTATION is the vertical-oriented rotational position measurement. This requires the X and Y axes to be in the vertical plane, with respect to the earth's surface. 3. This graph displays the vertical oriented, rotational position. This requires the X and Y axes to be in the vertical plane, with respect to the earth's surface. 4. Start and stop continuous reading of the ADIS16209's output data. The acquisition loop time provides rough control over sample times. Please note that this data will not have a high degree of coherence. 5. The acquisition loop time provides rough control over sample times. Please note that this data will not have a high degree of coherence. Rev. PrC | Page 9 of 11 ADISEVAL 6. Configure the ADIS16209's internal sample rate and filter response. Figure 8. ADIS16209 Evaluation Software 6 5 2 4 1 3 FIGURE FLAG NOTES: 1. Perform a single read of the ADIS16250's output data 2. Start and stop continuous reading of the ADIS16250's output data. The acquisition loop delay time provides rough control over sample times. Please note that this data will not have a high degree of coherence. 3. Select the file data logging option. 4. Configure the ADIS16250's internal sample rate and filter response. 5. Set the measurement range from the three options available in the ADIS16250. 6. Exercise the user calibration functions. 7. Note, for the ADIS16251, divide the data by a factor of 4. The ADIS16255 data requires no scaling. Figure 9. ADIS16250 Evaluation Software (c)2008 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. EB06335-0-7/08(PrC) Rev. PrC | Page 10 of 10