GENERAL DESCRIPTION
The ADISEVAL is a PC-based evaluation system for many of
the iSensor products. It comes with a Parallel Interface
Board, parallel interface cable, 2 12-pin ribbon cables, and the
iSensor CD, which contains product documentation and
evaluation software.
GETTING STARTED
Getting started with this system requires four simple steps.
1. Connect J2 of the Parallel Interface Board (see Figure 1) to
the appropriate power supply, using Table 1. For simplicity,
connect pin 1 to pin 4 and connect pin 2 to pin 3. Set the
voltage on the power supply per Table 2. Turn power off.
2. Install the ADIS16XXX/PCBZ evaluation board on the
Parallel Interface Board, using 2mm machine screws and
the two 12-pin ribbon cables, as shown in Figure 2. Make
sure that these cables are aligned correctly on each header
before applying power. Hook up the system to a PC using
the parallel cable.
3. Locate the product-specific evaluation software on the
iSensor CD or download it from:
www.analog.com/isensor-evaluation. See Tabl e 3 for a list
of products supported by each installation package.
4. Unpack the zip file and double click on the setup.exe file.
Follow the prompts to install the software.
5. Go to the created directory. In most cases, this will be a
subdirectoy under “C:\ProgramFiles\Analog Devices
iSensors\.” Double-click on the giveio.exe. Follow the
prompts to install this driver, which enables the parallel
port communications in the PC.
6. Double click on the ADIS*.exe file to start the software.
7. Click on “Interface” and select, “Parallel.” Enter the
address of the parallel port on the PC and click the “OK”
button. The parallel port address can be found under the
Device Manager in Windows XP.
The software contains help files that describe each function of
the software. The right button on the mouse has the ability to
speed up changes when the Pointer is placed over titles, graph
axes and waveform data.
See Figure 4 (ADIS16003, ADIS16006), Figure 5 (ADIS16080,
ADIS16100), Figure 6 (ADIS16201), Figure 7 (ADIS16203),
Figure 8 (ADIS16209) and Figure 9 (ADIS16250) for basic
software assistance.
Table 1. Power Supply Hook-up – J2
Pin Number Function
1 Digital I/O Power Supply
2 Common
3 Common
4 Sensor Power Supply
NOTE: No reverse polarity protection provided.
Table 2. Power Supply Voltages
Evaluation Board Power Supply Voltage
ADIS16003/PCBZ +3.0 to +5.25V
ADIS16006/PCBZ +3.0 to +5.25V
ADIS16060/PCBZ +4.75 to +5.25V
ADIS16080/PCBZ +4.75 to +5.25V
ADIS16100/PCB +4.75 to +5.25V
ADIS1620x/PCBZ +3.0 to +3.6V
ADIS1625x/PCBZ +4.75 to +5.25V
Table 3. Evaluation Software
Installation Package Filename Supported Products
003ES(x).zip ADIS16003 ADIS16006
ADIS16060 ADIS16080
ADIS16100
201ES(x).zip ADIS16201
203ES(x).zip ADIS16203
204ES(x).zip ADIS16024
209ES(x).zip ADIS16209
250ES(x).zip ADIS16250 ADIS16251
ADIS16255
ORDERING GUIDE
Model Package Description
ADISEVAL iSensor PC Evaluation System
ADISEVAL
Rev. PrC | Page 2 of 10
Pin 1
Figure 1iSensorPC Interface Board Layout
Preliminary Technical Data ADISEVAL
Rev. PrC | Page 3 of 11
12-pin
ribbon
cables
are
installed
here
Figure 2iSensor PC Interface Board with ADIS16201/PCBZ installed
ADISEVAL
Rev. PrC | Page 4 of 10
E9
E10
E11
E8
E5
E6
E3
E4
E1
VCC VDD
DNI
E13
E7
E2
DNI DNI
E12
DNI
DNI
J2
1725672
DNI
J1
Figure 3iSensorPC Evaluation Board Schematic
Preliminary Technical Data ADISEVAL
Rev. PrC | Page 5 of 11
12
3
4
5
FIGURE FLAG NOTES:
1. Set the Device type to ADIS16003 or ADIS16006.
2. Set the axis to measure. Test function exercises a self-test during a single sweep on the screen.
3. Plot and log data to files.
4. Set up data logging parameters.
5. Right click over Y-Axis to adjust scale and offset of the plot.
Figure 4. ADIS16003 and ADIS16006 Evaluation Software
ADISEVAL
Rev. PrC | Page 6 of 10
12
3
5
4
FIGURE FLAG NOTES:
1. Set the Device type to ADIS16060, ADIS16080 or ADIS16100.
2. Set the output channel to measure. Test function exercises a self-test during a single sweep on the screen.
3. Plot and log data to files.
4. Set up data logging parameters.
5. Right click over Y-Axis to adjust scale and offset of the plot.
Figure 5. ADIS16060, ADIS16080 and ADIS16100 Evaluation Software Screen
Preliminary Technical Data ADISEVAL
Rev. PrC | Page 7 of 11
1
2
3
4
FIGURE FLAG NOTES:
1. Perform a single read of the ADIS16201’s output data
2. Start and stop continuous reading of the ADIS16201’s output data. The acquisition loop delay time provides rough control over
sample times. Please note that this data will not have a high degree of coherence.
3. Select the file data logging option.
4. Configure the ADIS16201’s internal sample rate and filter response.
Figure 6. ADIS16201 Evaluation Software
ADISEVAL
Rev. PrC | Page 8 of 10
1
2
3
4
5
6
FIGURE FLAG NOTES:
1. Perform a single read of the ADIS16203’s output data
2. Start and stop continuous reading of the ADIS16203’s output data. The acquisition loop delay time provides rough control over
sample times. Please note that this data will not have a high degree of coherence.
3. Select the file data logging option.
4. Configure the ADIS16203’s internal sample rate and filter response.
5. Graphical orientation. Note that for incline angle - 0°, the corner dot would be in the lower, left hand corner.
6. Alarm monitoring. Note that these turn red on alarm condition. They maintain their status until the Reset button is pressed,
even if the error condition has cleared.
Figure 7. ADIS16203 Evaluation Software
Preliminary Technical Data ADISEVAL
Rev. PrC | Page 9 of 11
1
2
4
5
3
6
FIGURE FLAG NOTES:
1. Perform a single read of the ADIS16209’s output data
2. XINCL_OUT and YINCL_OUT are horizontal incline outputs. ROTATION is the vertical-oriented rotational position
measurement. This requires the X and Y axes to be in the vertical plane, with respect to the earths surface.
3. This graph displays the vertical oriented, rotational position. This requires the X and Y axes to be in the vertical plane, with
respect to the earths surface.
4. Start and stop continuous reading of the ADIS16209’s output data. The acquisition loop time provides rough control over
sample times. Please note that this data will not have a high degree of coherence.
5. The acquisition loop time provides rough control over sample times. Please note that this data will not have a high degree of
coherence.
ADISEVAL
Rev. PrC | Page 10 of 10
6. Configure the ADIS16209’s internal sample rate and filter response.
Figure 8. ADIS16209 Evaluation Software
12
3
4
5
6
FIGURE FLAG NOTES:
1. Perform a single read of the ADIS16250’s output data
2. Start and stop continuous reading of the ADIS16250’s output data. The acquisition loop delay time provides rough control over
sample times. Please note that this data will not have a high degree of coherence.
3. Select the file data logging option.
4. Configure the ADIS16250’s internal sample rate and filter response.
5. Set the measurement range from the three options available in the ADIS16250.
6. Exercise the user calibration functions.
7. Note, for the ADIS16251, divide the data by a factor of 4. The ADIS16255 data requires no scaling.
Figure 9. ADIS16250 Evaluation Software